Abstract Two-dimensional (2D) temperature and component concentration distribution based on tunable diode laser absorption spectroscopy is significant for combustion diagnosis, and the iterative algorithm plays an important role in the reconstruction of temperature and component concentration. It is found that the adaptive algebraic reconstruction technique and the least-square QR decomposition algorithm have good advantages in constructing 2D temperature and H2O concentration distribution. The simulated results show that four spectral absorption lines of H2O with wavelengths at 7 154.35, 7 153.75, 7 185.60 and 7 444.36 cm-1 are very suitable for measuring temperature and water vapor concentration distribution in high-temperature premix flame. Compared with the absorption lines at 7 444.36, 7 185.60, 7 154.35 and 7 153.75 cm-1, the absorption lines of CO2 and CH4 are very weak, the absorption lines of O2 and CO are almost no absorption in this band. Therefore, CO2, CH4, O2, CO and other gases in the combustion environment do not affect the absorption spectrum of H2O. By comparing the optimal relaxation factor, calculation time and reconstruction error of different algorithms, we find that the adaptive algebraic reconstruction technique has better reconstruction quality and shorter calculation time than the least square QR decomposition algorithm. Based on the AART algorithm, this paper further compares the 2D reconstruction effects of different absorption line pairs (7 444.36 and 7 185.60 cm-1, 7 154.35 and 7 153.75 cm-1) at 16, 32, 48 and 64 ray beams. The results show that the reconstruction results obtained from absorption lines 7 153.75 and 7 154.35 cm-1 are better than those obtained from absorption lines 7 185.60 and 7 444.36 cm-1. With the increased laser beams, the reconstructed results are closer to the assumed temperature and concentration distributions. The 32-beam arrangement is more suitable for the actual flame’s 2D temperature and concentration reconstruction. In order to analyze the ability of the AART algorithm to reconstruct different temperature and concentration distributions, this paper further simulates bimodal temperature and concentration distributions. The results show that with the increase of the ray beam, the temperature reconstruction error is always greater than the concentration reconstruction error, indicating that the ray number has a more obvious effect on temperature. In the bimodal distribution, the reconstruction error is the largest when the projected ray beam is 16, but the reconstruction results can also reflect temperature and concentration distribution trend.
|
Received: 2021-11-29
Accepted: 2022-06-26
|
|
|
[1] XIE Zheng-chao, WANG Fei, YAN Jian-hua, et al(谢正超,王 飞,严建华,等). Acta Physica Sinica(物理学报), 2015, 64(24): 240201.
[2] Cai W W, Ma L. Applied Optics, 2010, 49(4): 601.
[3] Liu C, Xu L J, Zhang C. IEEE Transactions on Instrumentation Measurement, 2014, 63(12): 3067.
[4] Zhang L, Wang F, Zhang H, et al. Chinese Optics Letters, 2016, 14(11): 111201.
[5] NA Yi-jun, LI Ning, HUANG Xiao-long, et al(那奕君,李 宁,黄孝龙,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2020, 40(12): 3686.
[6] Li N, Weng C S. Chinese Optics Letters, 2011, 9(6): 061201.
[7] Tan W H, Wang B L, Huang Z Y, et al. IEEE Sensors Journal, 2017, 17(24): 8234.
[8] LI Ning, TU Xin, HUANG Xiao-long, et al (李 宁,Tu Xin,黄孝龙,等). Acta Physica Sinica(物理学报), 2020, 69(22): 227801.
[9] Ni M, Zhang H, Wang F, et. al. Applied Thermal Engineering, 2016, 96: 421.
[10] Ma L, Li X, Sanders S T, et al. Optics Express, 2013, 21(1): 1152.
[11] Cai W W, Kaminski C F. Applied Physics B-Lasers and Optics, 2015, 119(1): 29.
[12] Wang F, Wu Q, Huang Q, et al. Optics Communications, 2015, 346: 53.
[13] Liu C, Xu L J, Chen J L, et al. Optics Express, 2015, 23(17): 22494.
[14] Liu C, Cao Z, Lin Y, et al. IEEE Transactions on Instrumentation and Measurement, 2018, 67(6): 1338.
[15] Verhoeven D. Applied Optics, 1993, 32(20): 3736.
|
[1] |
PAN Sun-qiang, HU Peng-bing, CHEN Zhe-min, ZHANG Jian-feng, LIU Su-mei. Measurement of Vapor Hydrogen Peroxide Based on Mid Infrared Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(04): 1102-1106. |
[2] |
LIU Yong-sheng, HE Jian-jun*, ZHU Gao-feng, YANG Chun-hua, GUI Wei-hua. A New Method for Second Harmonic Baseline Correction and Noise Elimination on Residual Oxygen Detection in Packaged Xilin Bottle[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(08): 2598-2602. |
[3] |
BAI Sha-sha, WANG Hai-shui* . Study on the Measurement of Infrared Spectrum for Discontinuous Sample[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(04): 943-947. |
[4] |
LANG Wen-jie1, CHEN Guo-guang2, TIAN Xiao-li2, XIN Chang-fan2 . Testing Research of Transient Temperature Distribution for the Barrel Surface by Speckle Pattern Interferometry [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(02): 355-358. |
[5] |
XIA Hui-hui, LIU Jian-guo, XU Zhen-yu, KAN Rui-feng, HE Ya-bai, ZHANG Guang-le, CHEN Jiu-ying . Reconstruction Research for Gas Concentration and Temperature of Flame Based on Algebraic Reconstruction Technique[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(10): 2697-2702. |
[6] |
WEI Min-hong1, 2, TONG Min-ming1, LI Su-wen2*, XIAO Jian-yu2 . MAX-DOAS Tomography Reconstruction for Gas Plume [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(08): 2252-2256. |
[7] |
ZHANG Li-fang, WANG Fei*, YU Li-bin, YAN Jian-hua, CEN Ke-fa . The Research for Trace Ammonia Escape Monitoring System Based on Tunable Diode Laser Absorption Spectroscopy [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(06): 1639-1642. |
[8] |
HUANG Yong1, 2,WANG Yan-lei2,ZHANG Zhi-guo2 . Impact of Introduction of O2 on the Welding Arc of Gas Pool Coupled Activating TIG[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(05): 1168-1172. |
[9] |
SHAO Xin1, 2, LIU Fu-gui1, DU Zhen-hui3*, WANG Wei3 . Absorption Spectrum of Quasi-Continuous Laser Modulation Demodulation Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(05): 1186-1190. |
[10] |
SONG Jun-ling, HONG Yan-ji, WANG Guang-yu, PAN Hu . Measurement of Nonuniform Temperature and Concentration Distribution by Absorption Spectroscopy Based on Least-Square Fitting [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(08): 2047-2050. |
[11] |
JIANG Zhi-shen, WANG Fei*, XING Da-wei, XU Ting, YAN Jian-hua, CEN Ke-fa. The Reconstruction of Two-Dimensional Distributions of Gas Concentration in the Flat Flame Based on Tunable Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(11): 2891-2896. |
[12] |
HU Xin-yue1, GAO Ming-xi1, REN Yu1, TAN Jian-yao1, LI Wei2, JIN Kun3, SHI San-zhi1, CAI Hong-xing1* . Study on Inversion of Temperature Distribution Based on Principal Components Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(10): 2789-2793. |
[13] |
ZOU De-bao1,2, CHEN Wen-liang1, 2*, DU Zhen-hui1, JIA Hao1, QI Ru-bin1, LI Hong-lian1,3, ZHEN Yang1, HOU Yan-xia1, XU Ke-xin1. Selection of Digital Filtering in the Escaping Ammonia Monitoring with TDLAS[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(09): 2322-2326. |
[14] |
JIAO Yang, XU Liang*, GAO Min-guang, FENG Ming-chun, JIN Ling, TONG Jing-jing, LI Sheng . Investigation on Remote Measurement of Air Pollution by a Method of Infrared Passive Scanning Imaging[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(07): 1754-1757. |
[15] |
LI Gang1, ZHAO Zhe1, WANG Hui-quan1, LIN Ling1, ZHANG Bao-ju2, WU Xiao-rong2* . Effect of Different Distribution of Components Concentration on the Accuracy of Quantitative Spectral Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(07): 1905-1908. |
|
|
|
|