The Research of Polarized Energy Dispersive X-Ray Fluorescence for Measurement Trace Cadmium by Geant4 Simulation |
OUYANG Zhou-xuan, MA Ying-jie, LI Dou-dou, LIU Yi |
Chendu University of Technology, Chendu 610059, China
|
|
|
Abstract Primary bremsstrahlung spectrum of X-ray tube has serious influence for trace Cadmium analysis in traditional EDXRF. Secondary targets with different geometry sizes were studied by Geant4 code. To enhance the efficiency of Geant4 simulations, the simulation processes were divided into three stages. In the first stage, primary spectra at different tube voltages were acquired using Geant4 code to simulate electrons of different voltages hitting anode target. In the second stage, Te and BaSO4 of different kinds and geometry as secondary target materials, simulated. The simulation results show that when Te, whose Kα1 energy (27.468 keV) closes to the absorption limit of Cd (26.711 keV) is used as the fluorescence target material, the characteristic peak intensity of Te increases rapidly before 100 μm with the increase of target thickness, and tends to be stable after 150 μm. However, the signal to noise ratio (SNR) reaches the maximum value of 21.434 at 80 μm. Due to the self-absorption effect of the secondary target material, SNR declines slightly and becomes stable after reaching the saturation absorption thickness. In different application scenarios, the materials of the secondary target should be various. When there is no limit to the measurement time, the secondary target with greater fluorescence intensity should be selected. But, when the measurement time is relatively short, the secondary target of greater SNR should be selected. In the third stage, output spectra of the secondary target were used to activate sample containing 0.01% cadmium element. The output spectra of the Te element secondary target were used to activate samples, and the peak-to-background ratio of the Kα1 peak of Cd element was 8.28. The primary spectra were used to activate samples, and the peak-to-background ratio is 2.29. Although it has a great increase, the scattering peak of the Te element always influences the Kα1 peak of the Cd element. The BaSO4 was selected as secondary target material because the characteristic X-ray energy is farther away from the Kα1 peak of the Cd element. The decrease of the peak-to-background ratio of target element could be weakened caused by the matrix elements of the sample. The peak-to-background ratio is increased to 14.179. The activation effect can be further improved by increasing the tube voltage of the X-ray tube. The optimal peak-to-background ratio of 21.431 could be obtained at the 70 kV tube voltage.
|
Received: 2021-03-13
Accepted: 2021-05-31
|
|
|
[1] Guthoff M, Brovchenko O, de Boer W, et al. Nuclear Instruments and Methods in Physics Research A,2012, 675: 118.
[2] Standzenieks P, Selin E. Nuclear Instruments and Methods, 1979, 165(1): 63.
[3] Nancy M Hepp, India C James. X-Ray Spectrometry,2016, 45(6): 330.
[4] Abuhani W A, Dasgupta-Schubert N, Cendejas L M V. Power Diffraction, 2014, 29(2): 159.
[5] I Afşin Kariper, Ilknur Üstündağ, Kiymet Deniz, et al. Microchemical Journal,2019, 148: 338.
[6] Maja D Gajic′-Kva( sˇ )čev,Milica D Maric′-Stojanovic′,Radmila M Jančic′-Heinemann. Chemistry Central Journal, 2012, 6: 102.
[7] Abuhani W A, Dasgupta-Schubert N, Villaseñor L M. Journal of Environmental Radioactivity,2015, 139: 33.
[8] Li Ming, Fan Tingting, Huang Jianbo, et al. IOP Conf. Ser.: Earth and Environmental Scinence, 2021, 687: 012008.
[9] YU Jie, HONG Xu, MA Ying-jie, et al(喻 杰,洪 旭,马英杰,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2016,36(10): 3429.
[10] Marguí E, Fontàs C, Van Meel K, et al. Analytical Chemistry, 2008, 80(7): 2357.
[11] CHEN Xi, ZHOU Ming-hui, WU Yan-xiang, et al(陈 曦, 周明慧, 伍燕湘, 等). Journal of Food Safety & Quality(食品安全质量检测学报), 2018,(10): 2331.
[12] ZHANG Li-jiao, TANG Bin, LI Fu-sheng, et al(张丽娇, 汤 彬, 李福生, 等). Nuclear Electronics & Detection Technology(核电子学与探测技术), 2019, (2): 173.
[13] Pedro Amaro, Jose Paulo Santos, Ana Samouco, et al. Spectrochimica Acta Part B: Atomic Spectroscopy, 2017, 130: 60.
[14] Johnston E M, Byun S H , Farquharson M J. X-ray Spectrometry, 2017, 46(2): 93.
|
[1] |
LI Qing-yuan, LI Jing, WEI Xin, SUN Mei-xiu*. Performance Evaluation of a Portable Breath Isoprene Analyzer Based on Cavity Ringdown Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(08): 2415-2419. |
[2] |
LIU Xiao-hong1,2, DENG Hua1, CHANG Lin2, ZHANG Wei2, JIANG Shan2*. Recent Progress of SERS for Environmental Estrogen Detection[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(10): 3038-3047. |
[3] |
LIU Bing-zhi1, LUO Zhi-yong2*, ZHENG Huai-li1, JIANG Lei2 . Study on the Catalytic Kinetic Spectrophotometric Determination of Trace Amounts of Iron(Ⅲ) and Its Reaction Mechanism [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(04): 1139-1144. |
[4] |
QIAN Wei, JIANG Qian, WANG Ru-hai, GONG Hua, HAN Yong . Determination of Trace Selenium in Plants by Hydride Generation Atomic Fluorescence Spectrometry with Program Temperature- Controlled Graphite Digestion[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(01): 235-240. |
[5] |
ZHENG Huai-li1,4,YAO Bing-hua2,YAO Jia-fei3, LI Hong4 . Research Development of Catalytic-Kinetic Spectrophotometric Determination of Trace Manganese[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(08): 1312-1314. |
[6] |
ZHENG Huai-li1, LONG Teng-rui2,ZHU Yan1 . Study on Determination of Trace Copper(Ⅱ) by Catalytic Kinetic Discoloring Spectrophotometry [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24(01): 114-117. |
|
|
|
|