Pressure Correction for Calibration-Free Measurement of Wavelength Modulation Spectroscopy in Atmospheric Environment |
LI Jin-yi1, FAN Hong-qing1, TIAN Xin-li1, LI Hong-lian2, WU Zhi-chao1, SONG Li-mei1 |
1. Key Laboratory of Advanced Electrical Engineering and Energy Technology, Tianjin Polytechnic University, Tianjin 300387, China
2. College of Quality & Technical Supervision, Hebei University, Baoding 071002, China |
|
|
Abstract Tunable diode laser absorption spectroscopy (TDLAS) has been widely used for trace gas detection due to high sensitivity and selectivity. However, measurement results of the optical gas sensors are constantly affected by the pressure of a target gas, especially in atmospheric environment. Most of the existing methods need to install pressure sensors on the spot to correct the measurement results. In this paper, a simple method was proposed for modification of the measured gas concentration without pressure sensor required. A gas absorption line with collision broadening dominant was selected, and wavelength modulation spectroscopy with the first-harmonic (WMS-1f) and the second-harmonic (WMS-2f) detection were performed simultaneously. The analytic expressions characterized by line broadening were established by the spacing between peak and valley of WMS-1f signal and the distance between two zero crossings of WMS-2f signal, respectively. The effect of pressure fluctuation on the measured gas concentration could be corrected by the WMS-1f or 2f signal, due to the relationship between line broadening and gas pressure. Carbon dioxide gas with concentration of 1 980 mg·m-3 was used to verify our method. The CO2 absorption located at 4 989.97 cm-1 was selected for concentration measurement with variable pressures and different modulation depths near atmospheric pressure. The influence of pressure variation on harmonic signals of carbon dioxide absorption spectrum was analyzed experimentally. The gas pressures were inverted by using the WMS-1f peak-valley spacing and the WMS-2f zero-crossing spacing respectively. Compared with the pressure data measured by gas pressure sensor, the pressure deviation was less than 1%. Therefore, the correctness of calculating pressure by analytic expression of harmonic spacing was verified. Finally, the gas concentration corrected by pressure compensation was carried out by using WMS-2f/1f technology. The results showed that the error of the corrected concentration by measuring harmonic spacing is less than 2% compared with that compensated by high-precision pressure gauge, which is consistent with the pressure uncertainty (less than 2%) derived by harmonic spacing. The feasibility and validity of this method are verified. It can further improve the measurement accuracy of TDLAS technology in gas concentration detection under high pressure fluctuation environment. This method is very simple and feasible without requirement of additional gas pressure sensors, which is especially suitable for high sensitivity and high precision open-path measurement of gas composition in atmospheric environment. Moreover, it can also be used for simultaneous measurement of gas concentration and pressure.
|
Received: 2019-03-08
Accepted: 2019-07-12
|
|
|
[1] Bolshov M A,Kuritsyn Yu A,Romanovskii Yu V. Spectrochimica Acta Part B: Atomic Spectroscopy,2015,106:45.
[2] Li Chuanliang,Wu Yingfa,Qiu Xuanbing. Appl. Spectrosc.,2017,71(5):809.
[3] Goldenstein C S,Strand C L. Appl. Opt.,2014,53:356.
[4] Christopher S,Goldenstein R,Mitchell Spearrin, et al. Applied Optics,2016,55(3):479.
[5] Wei Wei,Chang Jun,Huang Qingjie,et al. Sensor Review,2017,7(2):72.
[6] LU Wei-ye,ZHU Xiao-rui,LI Yue-sheng(卢伟业,朱晓睿,李越胜). Infrared and Laser Engineering(红外与激光工程),2018,47(7):155.
[7] Rieker G B,Jeffries J B,Hanson R K. Applied Optics,2009,48(29):5546.
[8] Goldenstein C S,Strand C L,Schultz I A,et al. Applied Optics,2014,53:356.
[9] Che Lu,Ding Yanjun,Peng Zhimin,et al. Chinese Physics B,2012,21(12):127803.
[10] Yan Yue,Du Zhenhui,Li Jinyi,et al. Chin. Phys. B,2018,27:2.
[11] Douglass K O,Olson D A. Metrologia,2016,53(3):96.
[12] Li Jinyi, Du Zhenhui, An Ying. Applied Physics B, 2015, 121(1): 7.
[13] Nevrlý Václav,Klečka Vít,Vašinek Michal. Measurement Science Review,2018,18(4):158.
[14] Bain J R P, Johnstone W, Ruxton K, et al. Journal of Lightwave Technology, 2011, 29(7): 987.
[15] CHEN Jia-yin,LI Jin-yi,LI Hao-dan,et al(陈佳音,李金义,李浩丹,等). Laser Journal(激光杂志),2018,(39):8.
[16] YUAN Jing-chao,ZHAO Jiang-shan,LI Hui,et al(袁靖超,赵江山,李 慧,等). Chinese Journal of Lasers(中国激光),2018,45(7): 19. |
[1] |
LIANG Wen-ke, WEI Guang-fen, WANG Ming-hao. Research on Methane Detection Error Caused by Lorentzian Profile Approximation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1683-1689. |
[2] |
ZHANG Le-wen1, 2, WANG Qian-jin1, 3, SUN Peng-shuai1, PANG Tao1, WU Bian1, XIA Hua1, ZHANG Zhi-rong1, 3, 4, 5*. Analysis of Interference Factors and Study of Temperature Correction Method in Gas Detection by Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(03): 767-773. |
[3] |
LIU Jiang-qing1, YU Chang-hui2, 3, GUO Yuan2, 3, LEI Sheng-bin1*, ZHANG Zhen2, 3*. Interaction Between Dipalmityl Phosphatidylcholine and Vitamin B2
Studied by Second Harmonic Spectroscopy and Brewster Angle
Microscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(05): 1484-1489. |
[4] |
WAN Liu-jie1, 2, ZHEN Chao3, QIU Zong-jia1, LI Kang1, MA Feng-xiang3, HAN Dong1, 2, ZHANG Guo-qiang1, 2*. Research of High Precision Photoacoustic Second Harmonic Detection Technology Based on FFT Filter[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(10): 2996-3001. |
[5] |
XIE Ying-chao1,2, WANG Rui-feng1,2, CAO Yuan1,2, LIU Kun1*, GAO Xiao-ming1,2. Research on Detecting CO2 With Off-Beam Quartz-Enhanced Photoacoustic Spectroscopy at 2.004 μm[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(09): 2664-2669. |
[6] |
MEI Jiao-xu, WANG Lei*, TAN Tu, LIU Kun, WANG Gui-shi, GAO Xiao-ming. A New Method of DFB Laser Frequency Stabilization Based on the Characteristics of the Second Harmonic[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(10): 2989-2992. |
[7] |
WU Hong-peng1, 2*, PENG Sai-nan1, ZHAO Jin-biao1, DONG Lei1, 2*, JIA Suo-tang1, 2. Research on High Sensitive Detection of CO2 Gas Based on Power-Boosted QEPAS Technology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(03): 840-844. |
[8] |
LI Chun-guang1, 2, 3, 4, DONG Lei2*, ZHENG Chuan-tao3, WANG Yi-ding3, LIN Jun1*. Mid-Infrared Trace Ethane Sensor Design and Stability Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(03): 959-963. |
[9] |
SHAO Xin, TANG Hai-mei, WANG Feng, LI Yun-long, TAN Pan-long. Research on Closed Indoor Oxygen Concentration of Quasi-Continuous Laser Modulation Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(12): 3713-3717. |
[10] |
ZHU Gao-feng1, 2, HU Xin1, ZHU Hong-qiu1*, HU En-ze1, ZHU Jian-ping3. The Multi-Beam Interference Suppression for Measuring Penicillin Vial’s Oxygen Concentration Based on Tunable Diode Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(02): 372-376. |
[11] |
ZHU Gao-feng1,2, YANG Chun-hua1, ZHU Hong-qiu1*, GUI Wei-hua1. Oxygen Concentration Detection and Calibration Method Improvement in Pharmaceutical Vial Based on Wavelength Modulation Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(10): 3133-3137. |
[12] |
QU Dong-sheng, HONG Yan-ji*, WANG Guang-yu, PAN Hu, WANG Ming-dong. Wavelength-Modulation Spectroscopy for Measurements of Gas Pressure, Temperature and H2O Concentration in High-Temperature Environment[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(05): 1339-1344. |
[13] |
QU Shi-min, WANG Ming, LI Nan . Mid-Infrared Trace CH4 Detector Based on TDLAS-WMS [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(10): 3174-3178. |
[14] |
CUI Hai-bin1, YANG Ke1, 2, ZHANG Long1, WU Xiao-song1, LIU Yong1, WANG An1, LI Hui3, JI Min1* . Tunable Diode Laser Absorption Spectroscopy (TDLAS) Detection Signal Denoising Based on Gabor Transform [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(09): 2997-3002. |
[15] |
DU Zhen-hui, ZHANG Zhe-yuan, LI Jin-yi, XIONG Bo, ZHEN Wei-meng . The Development of Ammonia Sensor Based on Tunable Diode Laser Absorption Spectroscopy with Hollow Waveguide [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(08): 2669-2673. |
|
|
|
|