Telemetry Research of NO2 Concentration in the Night Based on LED and DOAS Method |
YANG Lei1, 2, LI Ang1*, XIE Pin-hua1, 2, HU Zhao-kun1, 2, LIANG Shuai-xi1, 2, ZHANG Ying-hua1, 2, HUANG Ye-yuan1, 2 |
1. Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China
2. University of Science and Technology of China, Hefei 230026, China |
|
|
Abstract Aiming at the problem that existing passive DOAS methods using natural light sourcecannot detect the vertical distribution of NO2 and other trace gases at night, this paper proposes a method of DOAS measurement of NO2 based on the blue LED technology of narrowband light source, and uses this method to build the instrument system. Successfully realized the concentration measurement of NO2 gas by using the instrument system. This system is mainly composed of two parts: a light source emitting system and a telescope receiving system. The LED with the dominant wavelength of 450 nm is used as a light source to collect the scattered light of the light beam through the telescope. The scattered light received by the telescope is imported into the spectrometer through fiber coupling, DOAS principle using a computer for processing. The theoretical basis for DOAS is Lambert-Beer’s law, which describes the attenuation of the electromagnetic radiation energy as it penetrates the material. Based on this principle, the data processing can be summarized as follows: Firstly, a relatively clean spectrum is taken as the background reference spectrum, and the actual measured atmospheric spectrum is divided by the reference spectrum, and the digital high-pass filtering is used to remove the slow changes and then take the logarithm to obtain the optical thickness. Secondly, the instrument function is convolved with the high-resolution cross-section of NO2 to get the low-resolution absorption cross-section matched with the instrument used. Finally, the differential absorption cross-section is combined with the processed differential optical thickness, and the least square method is used to fit out the NO2 concentration value with the light path L. At the same time, by adjusting the angle of light emission and the receiving angle of the telescope, the NO2 concentration at different positions can be measured, and then the three-dimensional distribution of NO2 gas concentration can be obtained. Under the condition ofthe algorithm determined, the quality of the LED light spectrum is particularly important for the reliability of the instrument system. As the temperature and drive current have a greater impact on the LED spectrum, in order to ensure that the LEDs are in the best working condition, carried out the LED spectral temperature and drive current sensitivity experiments. The test results show that to make sure the acquired spectrum is stable and of high quality, the LEDs should operate at a temperature lower than 20 ℃, and the drive current needs to be controlled within 1. 5A, and both of them should have a small fluctuation range. In the experiments, the LEDs are working with the temperature of 10~15 ℃, the driving current of 1.4 A and the accuracy of driving current of ±1 mA, and all the conditions can meet the experimental requirements. In order to improve the LED array density, to get a more focused beam of light, LED base block with a regular hexagonal structure is chose, and all the blocks have 7 LEDs connected in series, and the blocks are connected in parallel. Compared with using rectangular structure, the space utilization increased by 8% with using regular hexagon structure. At the same time, it is easier to expand and more convenient to maintenance with the working drive of 1.4 A and the maximum voltage of 23.8 V. In order to verify the feasibility of the program and the reliability of system, laboratory tests and outdoor experiments were conducted. The concentration of the sample gas of NO2 used in the laboratory was 1 642.86 mg·m-3 and the uncertainty was 5%. The system measurement was 1 607.54 mg·m-3 with an error of 2.15% from the nominal value, within the uncertainty range of the calibration. The calculated system test line was 0.014 3 mg·m-3(6.942 ppb), therefore, the measurement result can be considered as accurate. The results of outdoor experiments were compared with the data of NO2 given by the national control station over the same period. The results showed that the deviations of the results were within 10% in the corresponding time periods. The linearity of the data fit well with the correlation coefficient of 0.967, indicating that the system NO2 measured results were accurate. The results of this paper show that the DOAS method based on the blue LED with narrowband light source can measure the vertical distribution of NO2 gas at night, while ensuring the stability of LED light source. It provides a new idea for measuring the vertical distribution of trace gases in atmosphere, especially for measuring the distribution of trace gases in nighttime conditions.
|
Received: 2018-03-08
Accepted: 2018-07-10
|
|
Corresponding Authors:
LI Ang
E-mail: angli@aiofm.ac.cn
|
|
[1] Andreae M O, Jones C D, Cox P M. Nature, 2005, 435: 1187.
[2] Lü Wei-yu, YUAN Ke’e, WEI Xu,et al(吕伟煜,苑克娥,魏 旭,等). Infrared and Laser Engineering(红外与激光工程),2016, 45(3): 0330001-1.
[3] Platt U, Perner D, Patz H. Geophys. Res.,1979, 84(10): 6329.
[4] Platt U, Perner D, Patz H. Geophys. Res., 1979, 84(10): 6329.
[5] ZHENG Ni-na, XIE Pin-hua, LING Liu-yi,et al(郑尼娜,谢品华,凌六一,等). Acta Optica Sinica(光学学报), 2013, 33(3): 0301007-1.
[6] Christoph Kern, Sebastian Trick, Bernhard Rippel,et al. Appl. Opt.,2006, 45(9): 2077.
[7] Chan K L, Pöhler D, Kuhlmann G,et al. Atmos. Meas. Tech.,2012, 5: 901.
[8] ZHANG Bao, GAO Chao, GUO Yong-cai, et al(张 豹,高 潮,郭永彩,等). Acta Photonica Sinica(光子学报),2018,47(2):61.
[9] LING Liu-yi, XIE Pin-hua, QIN Min, et al(凌六一,谢品华,秦 敏,等). Acta Optica Sinica(光学学报),2011,31(12):1230003.
[10] WANG Jian, HUANG Xian, LIU Li,et al(王 健,黄 先,刘 丽,等). Chinese Journal of Luminescence(发光学报), 2008, 29(2): 358.
[11] QIN Min, XIE Pin-hua, LIU Jian-guo,et al(秦 敏,谢品华,刘建国,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2005, 25(9): 1463. |
[1] |
ZHENG Ni-na1, 2*, XIE Pin-hua1, QIN Min1, DUAN Jun1. Research on the Influence of Lamp Structure of the Combined LED Broadband Light Source on Differential Optical Absorption Spectrum
Retrieval and Its Removing Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(11): 3339-3346. |
[2] |
DUAN Ming-xuan1, LI Shi-chun1, 2*, LIU Jia-hui1, WANG Yi1, XIN Wen-hui1, 2, HUA Deng-xin1, 2*, GAO Fei1, 2. Detection of Benzene Concentration by Mid-Infrared Differential
Absorption Lidar[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(11): 3351-3359. |
[3] |
CHANG Zhen1, ZHONG Ming-yu2*, SU Jing-ming1, 2, SI Fu-qi1, WANG Yu3, ZHOU Hai-jin1, DOU Ke1, ZHANG Quan1. Study on the Reconstructing the NO2 Gas Distribution in a Vertical Plane Using MAX-DOAS[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(08): 2413-2418. |
[4] |
PU Gui-juan1, 2, CHENG Si-yang3*, LI Song-kui4, LÜ Jin-guang2, CHEN Hua5, MA Jian-zhong3. Spectral Inversion and Variation Characteristics of Tropospheric NO2
Column Density in Lhasa, Tibet[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1725-1730. |
[5] |
ZHANG Zhi-dong1, 2, XIE Pin-hua1, 2, 3*, LI Ang2, QIN Min2, FANG Wu2, DUAN Jun2, HU Zhao-kun2, TIAN Xin4LÜ Yin-sheng1, 2, REN Hong-mei2, REN Bo1, 2, HU Feng1, 2. Study of SO2 and NOx Distribution and Emission in Tangshan Based on Mobile DOAS Techniques[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(05): 1651-1660. |
[6] |
REN Hong-mei1, 2, LI Ang1*, HU Zhao-kun1, XIE Pin-hua1, 2, 3, XU Jin1, HUANG Ye-yuan1, 2, LI Xiao-mei1, 2, ZHONG Hong-yan1, 4, ZHANG Hai-rong1, 2, TIAN Xin1, 4, REN Bo2, ZHENG Jiang-yi1, 2, WANG Shuai5, CHAI Wen-xuan5. Measurement of Water Vapor Absorption in the Ultraviolet Band Using MAX-DOAS and Evaluation of Its Influence on DOAS Retrieval[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(10): 3314-3320. |
[7] |
XU Heng1, LIU Hao-ran1*, JI Xiang-guang2, LI Qi-hua1, LIU Guo-hua1, OU Jin-ping1, ZHU Peng-cheng1. Study on the Tropospheric Column Density of NO2 in Shanghai Based on MAX-DOAS[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(09): 2720-2725. |
[8] |
TIAN Xin1, 3, REN Bo3, 5, XIE Pin-hua1, 3, 4, 5, MOU Fu-sheng2*, XU Jin3, LI Ang3, LI Su-wen2, ZHENG Jiang-yi3LI Xiao-mei3, REN Hong-mei3, HUANG Xiao-hui1, PAN Yi-feng1, TIAN Wei1. Study on Vertical Distribution of Atmospheric HONO in Winter Based on Multi-Axis Differential Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(07): 2039-2046. |
[9] |
SU Jing-ming1, 2, 3, ZHAO Min-jie1, ZHOU Hai-jin1, YANG Dong-shang1, 2, HONG Yan3, SI Fu-qi1*. On-Orbit Degradation Monitoring of Environmental Trace Gases Monitoring Instrument Based on Level 0 Data[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(03): 686-691. |
[10] |
XI Liang1,2, SI Fu-qi1*, JIANG Yu1, ZHOU Hai-jin1, QIU Xiao-han1, CHANG Zhen1. Ground-Based IDOAS De-Striping by Weighted Unidirectional Variation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(02): 627-633. |
[11] |
LIU Guo-hua, LI Qi-hua*, OU Jin-ping, XU Heng, ZHU Peng-cheng, LIU Hao-ran. Passive Spectrum Measurement of HCHO in Chongqing Area Based on MAX-DOAS[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(01): 243-247. |
[12] |
CHENG Liang-xiao1, 2, TAO Jin-hua1*, ZHOU Hai-jin3, YU Chao1, FAN Meng1, WANG Ya-peng4, WANG Zhi-bao5, CHEN Liang-fu1. Evaluations of Environmental Trace Gases Monitoring Instrument (EMI) Level 1 Data[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(12): 3881-3886. |
[13] |
CHEN Dong-yang1, ZHOU Li1*, YANG Fu-mo1, WANG Wei-gang2, GE Mao-fa2. Application Progress of Cavity-Enhanced Absorption Spectroscopy (CEAS) in Atmospheric Environment Research[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(09): 2688-2695. |
[14] |
ZHU Peng-cheng1, LIU Hao-ran1*, JI Xiang-guang2, LI Qi-hua1, LIU Guo-hua1, TIAN Yuan1, XU Heng1. Study on Measurement of Troposphereic NO2 in Beijing by MAX-DOAS[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(07): 2153-2158. |
[15] |
JIA Gui-hong1, 2*, ZHANG Jian-jun1, ZHENG Hai-ming2. Research on FFT+FT Spectrum Zooming Method for Differential Optical Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(07): 2116-2121. |
|
|
|
|