Abstract Taking into account of the slow measuring speed, low measuring accuracy and complex system structure of the existing Stokes parameters acquisition method , a new acquisition method of full-Stokes parameters in double Liquid Crystal Variable Retarder (LCVR) and Acousto-Optical Tunable Filter (AOTF) combining spectral polarization imaging system is established. Based on the working principle of AOTF and LCVR, this paper has explored the basic detection principles of the system before a new method for fast acquisition of full-Stokes parameters is proposed. According to polarization analysis, fixed control voltage is selected as the basis, in which four fixed voltages are selected as the control voltages of LCVR, and two identical LCVR are controlled at the same time to complete phase modulation of optical waves. The Stokes parameters can be obtained with four groups of phase delay which are plunging the same. Besides, a LCVR controller is designed to stabilize the output square wave whose root mean square is 0 to +8.72 V. Then, its calibration is carried out in order to realize precise modulation of different optical waves. Finally, an experimental prototype is set up to test the target, with three polarizing plates P1, P2 and P3 whose polarization directions being 0, 90 and 45 degrees respectively as the targets of polarization measurement. The full-Stokes parameter figures with a wavelength of 632 nm is obtained; paper painted with red, green and blue lines and the angle of 30 degrees are used as the target of spectral measurement, spectral imaging on 71 channels of 400~750 nm spectral range (spectral bandwidth of 5 nm), the spectrum curves of red, green, blue are acquired which accordant with their theoretical spectral graphs. The results show that not only all the Stokes parameters can be obtained quickly and accurately with the system, but also the structure of system is simplified and the imaging quality is improved.
|
Received: 2016-05-04
Accepted: 2016-10-29
|
|
Corresponding Authors:
LIU Shun
E-mail: liushun_ls@yeah.net
|
|
[1] Kurosaki H. Advances in Space Research, 2007, 39(1): 185.
[2] Jihwan Kim, Michael J Escuti. Proceedings of SPIE, 2008, 7086: 708603.
[3] ZHAO Yong-qiang, PAN Quan, CHENG Yong-mei. Natural Defense Industry Press, 2011. 15.
[4] HUANG Hong-lian, YI Wei-ning, QIAO Yan-li. Acta Optica Sinica, 2014, 34(10): 1028001.
[5] HU Qiao-yun, YANG Wei-feng, HU Ya-dong. Acta Optica Sinica, 2015, 35(2): 0211004.
[6] Gupta N. SPIE Sensing Technology+ Applications. International Society for Optics and Photonics, 2014: 90990N-90990N-11.
[7] ZHAO Hai-bo, LI Huan, LIN Xu-ling. Spectroscopy and Spectral Analysis, 2015,35(4): 1129.
[8] WEI Xiao-yan, NIE Shou-ping. Journal of Nanjing Normal University·Natural Science Edition, 2001, 24(3): 58.
[9] ZHAO Rong, GU Guo-hua, YANG Wei. Laser Technology, 2016, 40(2): 227.
[10] HE Chao, CHANG Jin-tao, WANG Yong. Journal of Infrared and Millimeter Waves, 2016, 35(1): 57.
[11] ZHANG Xue-bing, LI Yan-qiu, ZHENG Meng. Journal of Laser, 2015(7): 237.
[12] CHENG Yi, TANG Zhi-lie. Optica Sinica, 2014,(6): 102.
[13] Gupta N, Dahmani R, Choy S. Optical Engineering, 2002, 41(5): 1033.
[14] Gupta N. Journal of Biomedical Optics, 2005, 10(5): 051802.
[15] Gupta N, Suhre D R. Applied Optics, 2007, 46(14): 2632.
[16] XUE Peng, WANG Zhi-bin. Journal of Laser, 2016, 43(8): 275.
[17] WANG Yao-li, ZHANG Rui, WANG Zhi-bin. Spectroscopy and Spectral Analysis, 2015, 35(8): 2362.
[18] LI Ke-wu, WANG Zhi-bin, ZHANG Rui. Acta Phys. Sinica, 2015, 64(14): 140702.
[19] ZHANG Chun-guang. Harbin Institute of Technology, 2008.
[20] LIU Shu-qin, WANG Bin-yong, XU Rui. Infrared and Laser Engineering, 2015, 44(4): 1343.
[21] LI Ke-wu, WANG Zhi-bin, ZHANG Rui. Chinese Journal of Laser, 2015, 42(1): 0108001-3.
[22] ZHANG Ying, ZHAO Hai-bo, CHENG Yi. Spectroscopy and Spectral Analysis, 2011, 31(5): 1375. |
[1] |
LIU Lu1,2,3, CHEN Yuan-yuan1,2,3*, ZHANG Rui1,2,3, WANG Zhi-bin1,2,3, XUE Peng1,3, LI Xiang2. Study on 0 Level Interference Suppression Method for Hyperspectral Imaging Based on AOTF[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(10): 3182-3186. |
[2] |
XUE Peng1, 2, 3, WANG Zhi-bin1, 2, 3*, ZHANG Rui1, 3, XUE Rui2, 3, ZHAO Tong-lin1, 3 . The Study of Precision Measurement Technology Based on AOTF Imaging Spectrum [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(08): 2664-2668. |
[3] |
WANG Yu-jiang1, WANG Zhi-bin1, 2, 3*, WAN Yao-li1, SONG Yan-peng1, LI Jin-hua1, ZHANG Min-juan1, XUE Rui1 . The Study on the Influence of Spectral Diffraction Efficiency Based on the Matching Network of Wide Spectrum AOTF [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(07): 2300-2305. |
[4] |
WANG Yao-li1, 2, 3, WEN Ting-dun1, 2, WANG Zhi-bin1, 2, 3*, ZHANG Rui1, 2, 3, SONG Yan-peng1, 2, 3 . Chromatism Analysis of Multispectral Imaging System Based on AOTF and Hardware Compensation Strategy [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(07): 2306-2311. |
[5] |
ZHANG Rui1, 2, 3, CHEN You-hua1, 2, 3*, LI Shi-wei1, 2, 3, WANG Zhi-bin1, 2, 3*, WEN Ting-dun2, 3, WANG Yao-li1, 2, 3, LI Ke-wu1, 2, 3. The Research of Spectral Polarization Imaging Detection System Based Dual-AOTFs[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(05): 1549-1553. |
[6] |
LIU Kang, GAO Zhi-fan, WU Qiong-shui*, ZENG Li-bo* . AOTF-Based Imaging Spectrometer and Its Applications in the Identification of Metameric Targets[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(04): 1134-1137. |
[7] |
ZHAO Hui-jie, ZHOU Peng-wei*, ZHANG Ying, LI Chong-chong . Lateral Chromatic Aberrations Correction for AOTF Imaging Spectrometer Based on Doublet Prism[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(10): 2869-2874. |
[8] |
HU Shan-zhou1, CHEN Fen-fei2, ZENG Li-bo2, WU Qiong-shui2* . Testing Method Research for Key Performance Indicator of Imaging Acousto-Optic Tunable Filter (AOTF)[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(01): 271-274. |
[9] |
ZHAO Hui-jie, CHENG Xuan*, ZHANG Ying, LI Chong-chong . Analysis of the Noise and Signal-to-Noise of AOTF Imaging Spectrometer Based on EMCCD [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(12): 3422-3428. |
[10] |
LIU Hong-ying1, LI Qing-li1*, GU Bin1, WANG Yi-ting2, XUE Yong-qi3 . Performance Analysis And Radiometric Correction of Novel Molecular Hyperspectral Imaging System[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(11): 3161-3166. |
[11] |
LIU Hong-ying1, LI Qing-li1*, WANG Yi-ting2, LIU Jin-gao1, XUE Yong-qi3 . Molecular Hyperspectral Imaging (MHSI) System and Application in Biochemical Medicine[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(10): 2593-2597. |
|
|
|
|