|
|
|
|
|
|
The Investigation of K Shell X-Ray Fluorescence Parameters for Sulphur Atom in Different 1,2,4-Triazoles |
N. Kup Aylıkcı1*, Y. Unver2, V. Aylıkcı3, D. Unluer2, E. Dugdu2 |
1. Energy Systems Engineering, Faculty of Engineering and Natural Sciences, Iskenderun Technical University 31600, Hatay, Turkey
2. Department of Chemistry, Faculty of Arts and Sciences, Karadeniz Technical University 61080, Trabzon, Turkey
3. Metallurgical and Materials Engineering, Faculty of Engineering and Natural Sciences, Iskenderun Technical University 31200, Hatay, Turkey |
|
|
Abstract The measurement of K shell fluorescence parameters is an easy and practical way to investigate the electronic structures of elements in alloys, compounds or complexes. Since the number of valence electrons will change the screening effect, the measured parameters will be affected from the changes. In this study, the measured parameters were investigated for sulphur element according to the number of CH2 groups. For the experimental measurements, the samples were excited by 59.5 keV γ rays from a 241Am annular radioactive source. The emitted K X-rays from the samples were counted by ab Ultra-LEGe detector with a resolution of 150 eV at 5.9 keV.
|
Received: 2016-09-07
Accepted: 2016-12-29
|
|
Corresponding Authors:
N. Kup Aylıkcı
E-mail: nuray.aylikci@iste.edu.tr
|
|
[1] ünver Y, Dügdü E, Sancak K, et al. Turk. J. Chem., 2008,32: 441.
[2] ünver Yasemin, Sancak Kemal, elik Fatih, et al. European Journal of Medicinal Chemistry,2014,84: 639.
[3] Eswaran S, Adhikari A V,Shetty N S. Eur. J. Med. Chem.,2009,44: 4637.
[4] Kucukguzel I, Kucukguzel S G, Rollas S, et al. Bioorg. Med. Chem. Lett., 2001, 11: 1703.
[5] Abd El-Galil E Amra, Mohamed H Sherif, Mohamed G Assy, et al. European Journal of Medicinal Chemistry,2010,45: 5935.
[6] Gauthier J Y, Leblanc Y, Black W C, et al. Bioorg. Med. Chem. Lett.,1996,6: 87.
[7] Fink R W, Jopson R C, Mark H,et al. Rev. Mod. Phys., 1966, 38: 513.
[8] Kavcic M, Dousse J-Cl, Szlachetko J, et al. Nucl. Instrum. Methods Phys. Res., Sect. B, 2007, 260: 642.
[9] Torres Deluigi M,Riveros J A. Chem. Phys., 2006, 325: 472.
[10] Kavcic M, Karydas A G,Zarkadas C. Nucl. Instrum. Methods Phys. Res., Sect. B, 2004, 222: 601.
[11] Perez P D, Carreras A C,Trincavelli J C. J. Phys. B: At. Mol. Opt. Phys., 2012, 45: 025004.
[12] Torres Deluigi M, Perino E, Olsina R, et al. Spectrochim. Acta, 2003, 58: 1699.
[13] Suguriura C, Kitamura M, Muramatsu S, et al. Jpn. J. Appl. Phys., 1989, 25: 1525.
[14] Aylikci V, Cengiz E, Apaydin G, et al. Chem. Phys. Lett.,2008,461: 332.
[15] Scofield J H. At. Data and Nucl. Data Tables, 1974, 14: 121.
[16] Krause M O,Oliver J H. J. Phys. Chem. Ref. Data, 1979, 8: 329.
[17] 瘙塁ahin M, Demir L, Budak G. Appl. Radiat. Isotopes, 2005, 63: 141.
[18] Krause M O. J. Phys. Chem. Ref. Data, 1979, 8: 307.
[19] Hubbel J H, Trehan P N, Singh N, et al. J. Phys. Chem. Ref. Data,1994,23: 339. |
[1] |
V. Aylkc1*, Y. ünver2, N. Kup Aylkc3, E. T r o lu4, K. Sancak2, Z. Laap2 . Structure Effect on K Shell Fluorescence Parameters at Bis-4-Bromobenzyl-1,2,4-Triazol-3-Ones[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(12): 4120-4124. |
[2] |
V. Aylikci. K Shell and L Subshell Photoeffect Cross-Sections of Some Elements in the Atomic Range 50≤Z≤65 at 59.5 keV[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(01): 29-33. |
|
|
|
|