|
|
|
|
|
|
Automatic Regulating System Design for Fourier Infrared Spectrometer Beam Splitter |
DING Fan, ZENG Li-bo, WU Qiong-shui* |
Electronic Information School, Wuhan University, Wuhan 430079, China |
|
|
Abstract In order to improve the accuracy of interference of Fourier transform infrared spectrometer, we design an automatic regulating system based on integrative beam splitter. Using optical glue to fix the prism and beam splitter. Three adjustment structures was set on the integrative beam splitter. The O point is fixed as the reference point, and piezoelectri ceramics are loaded on the X point and Y point.Using the piezoelectri ceramics to drive beam splitter for tiny displacement adjustment.When the moving mirror moves in constant speed, using four quadrant detector to test the phase difference of three signals. Then three signals are enlarged, filtered and digitized. Using the ECAP of DSP to catch three signals and Using the increment PID to conduct real time control the adjustment of three signals based on phase difference. These three signals is sampled by the AD of DSP. All the information measured can communication with the host PC through USB2.0, then finally reading collection data and real-time demarcating the wave show. The ultraviolet radiator is installed on the holder, the irradiation of ultraviolet light on optical glue is increased when the ajustment start. So that the integrative beam splitter is made which can meet the demand of fourier transform infrared spectrometer. The experimental results show that the design of automatic regulating system based on integrative beam splitter has advantages of simple structure, high adjustment accuracy which can meet the demand of common infrared beam splitter.
|
Received: 2016-06-26
Accepted: 2016-10-17
|
|
Corresponding Authors:
WU Qiong-shui
E-mail: qswu@whu.edu.cn
|
|
[1] Tatsuyuki Tanahashi, Masaya Toda, Hidetoshi Miyashita, et al. IEEE Xplore, 2013 W4D.007.
[2] WENG Shi-fu(翁诗甫). Fourier Transform Infrared Spectroscopy Analysis,2nd Ed.(傅里叶变换红外光谱分析, 第2版). Beijing: Chemical Industry Press(北京: 化学工业出版社),2010. 62.
[3] Sun Xiaojie, Mao Jianhua, Dai Zuoxiao, et al. Optical System Technologies for Manufacturing and Testing, 2012, doi:10.1117/12.975181.
[4] XIE Fei, FENG Fei, WANG Fu-bei, et al(谢 非, 冯 飞, 王府北, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2015, 35(8): 2343.
[5] SI Dong-sen, LI Zeng-zhi, WANG Xiao-xu(司栋森, 李增智, 王晓旭). Journal of Xi’an Jiaotong University(西安交通大学学报), 2012, 04: 13.
[6] Warren J. Smith (ed.): Modern Optical Engineering: Mc Graw Hill Education, 2011.
[7] Lü Jin-guang, LIANG Jing-qiu, LIANG Zhong-zhu(吕金光, 梁静秋, 梁中翥). Acta Physica Sinica(物理学报), 2012, 14: 91.
[8] SUN Bao-guang, TAN Ren-bing, ZHANG Qi-yi(孙宝光, 谭仁兵, 张启义). Piezoelectrics & Acoustooptics(压电与声光), 2015, 5: 888.
[9] ZHAO Xiu-wei, REN Jian-yue(赵秀伟, 任建岳). Optics and Precision Engineering(光学精密工程), 2013, 12: 3214.
[10] YANG Kun, ZENG Li-bo, LEI Jun-feng, et al(杨 琨, 曾立波, 雷俊锋, 等). Journal of Huazhong University of Science & Technology·Natural Science Edition(华中科技大学学报·自然科学版), 2009, 3: 5. |
[1] |
XIE Fei, FENG Fei, WANG Fu-bei, WU Qiong-shui*, ZENG Li-bo* . Moving Mirror Scanning System Based on the Flexible Hinge Support [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(08): 2343-2347. |
[2] |
XIE Fei, WU Qiong-shui*, ZENG Li-bo* . Biological Process Oriented Online Fourier Transform Infrared Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(08): 2357-2361. |
[3] |
SHI Lei, LI Kai, GAO Zhi-fan, ZENG Li-bo, WU Qiong-shui* . Design of A Compact Structure Interferometer [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(08): 2294-2298. |
[4] |
SHI Lei, LIU Jia, ZHENG Xin-wen, ZENG Li-bo, WU Qiong-shui*. An Interferometer Design for Fourier Transform Infrared Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(06): 1712-1716. |
[5] |
ZHANG Min-juan2, ZHANG Ji-long1, 2*, WANG Zhi-bin1, 2, JING Ning2, HAO Jian2 . Phase Correction Technology Research and Improvement Based on Single-Sided Interferograms in FTIR [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(05): 1203-1208. |
[6] |
LI Sheng, GAO Min-guang, ZHANG Yu-jun, LIU Wen-qing, XU Liang, TONG Jing-jing, CHENG Si-yang, JIN Ling,WEI Xiu-li, WANG Ya-ping, CHEN Jun. Monitoring and Analysis of Urban Ozone Using Open Path Fourier Transform Infrared Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(12): 3256-3259. |
[7] |
FU Jian-guo1,2,LIANG Zhong-zhu1,LIANG Jing-qiu1* . Influence of Extended Light Source on Spectral Reconstruction in a Micro FTIR [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(06): 1723-1726. |
[8] |
LIU Shi-yuan1,ZHANG Chuan-wei2,SHEN Hong-wei2,GU Hua-yong2 . Model-Based FTIR Reflectometry Measurement System for Deep Trench Structures of DRAM[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29(04): 935-939. |
[9] |
LIU Zhi-ming,GAO Min-guang,LIU Wen-qing,LU Yi-huai,ZHANG Tian-shu,XU Liang,WEI Xiu-li. The Study of Instrument Response Function of FTIR Detectors[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28(08): 1786-1789. |
|
|
|
|