光谱学与光谱分析 |
|
|
|
|
|
Study on Internal Information of the Two-Layered Tissue by Optimizing the Detection Position |
LIU Yan1,2, YANG Xue1,2, ZHAO Jing3, LI Gang1,2, LIN Ling1,2* |
1. State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China 2. Tianjin Key Laboratory of Biomedical Detecting Techniques & Instruments, Tianjin University, Tianjin 300072, China 3. School of Chinese Medicine Engineering, Tianjin University of Traditional Chinese Medicine, Tianjin 300193, China |
|
|
Abstract As to most methods of detecting the inner information of inhomogenous tissue, a significant issue is that the detection position is ambiguous because of the complexity of human tissue structure and discrepancies among individuals. This paper studies the best source-detector distance (SDSbest) to detect internal information of a fat-muscle tissue with spatially resolved diffuse reflectance spectra. In order to weaken the measurement error caused by the discrepancies among individuals and multiple backscattered photons, and according to the transmission model of light in complex biological tissue, then we added the constraint condition——two ideal “banana shape” paths——to define the effective photon ratio(SNR), which was used to select the best source-detector separations (SDSbest), and the results from Monte Carlo simulation modified by adding constraint condition were statistically analyzed, and we regard the SNR as a basis and analyze the relationship between the fat thickness (hf),the absorption coefficient of a fat layer (μaf),the absorption coefficient of a muscle layer (μam) and the source-detector distance (SDS), and hf is used as the independent variable to develop a linear regression model to predict SDSbest. The result showed that μaf and μam have no effect on SDSbest when 0<hf<0.6 cm, and the correlation coefficient of the linear regression model is 0.991 8; Randomly select hf=0.12 and 0.22 cm, the prediction error is 0.030 14 and 0.020 16 respectively, the error can be controlled within 5%. This method can select the SDSbest much easier and faster to detect the inner information of turbid tissue, and to weaken the interference from the non-target layer and multiple backscattered photons.
|
Received: 2015-07-07
Accepted: 2015-11-20
|
|
Corresponding Authors:
LIN Ling
E-mail: linling@tju.edu.cn
|
|
[1] Bogomolov A, Melenteva A. Chemometrics and Intelligent Laboratory Systems,2013, 126(15): 129. [2] Poliana M Santors, Edenir R Pereira-Filho, Luis E Rodriguez-Saona. Agricultural and Food Chemistry,2013, 61(6): 1205. [3] Georg Hennig, Herbert Stepp, Ronald Sroka. Applied Optics(USA),2013, 52(5): 1066. [4] Lorilee S L Arakaki, Kenneth A Schenkman, Wayne A Ciesielski. Analytica Chimica Acta, 2013, 785: 27. [5] Michelle L Davis, Thomas J Barstow. Respiratory Physiology & Neurobiology, 2013, 186(2): 180. [6] Kung-Bin Sung, Kuang-Wei Shih, Fang-Wei Hsu. Journal of Biomedical Optics,2014, 19(7): 077002-1. [7] Li Chenxi, Zhao Huijuan, Zheng Jiaxiang. Acta Optica Sinica, 2012, 32(7): 0717001-1. [8] Wu Kai-jie, Li Gang, Lin Ling. Journal of Tianjin University, 2012, 32(3): 755. [9] Wang Liyun, Li Gang, Li Zhe. Spectroscopy and Spectral Analysis,2014, 34(4): 1026. [10] Wang L, Jacques S L, Zheng L. Computer Methods and Programs in Biomedicine, 1995, 47: 131. [11] Ye Yang, Olusola O Soyemi, Michelle R Landry. Optics Express, 2005, 13(5): 1570. [12] Lin Ling, Chen Yaqin, Li Gang. Chinese Journal of Biomedical Engineering, 2003, 23(5): 419. |
[1] |
WU Ming-lei, LIU Rong*, XU Ke-xin. Simulation Study of Measurement Method Based on Temperature Insensitive Source-Detector Separation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(10): 3163-3168. |
[2] |
YANG Xue1, 2, LI Gang1, 2, LIU Yan1, 2, ZHAO Jing3, LIN Ling1,2* . The Acceleration of Monte Carlo Simulation for Optical Transmission in Large Space Biological Tissue [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(11): 3476-3480. |
[3] |
WANG Yu-hua1, YANG Hong-qin1, XIE Shu-sen1*, YE Zhen2, SU Yi-ming2 . Spectral Characteristics of Normal Breast Samples in the 350-850 nm Wavelength Range [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29(10): 2751-2755. |
[4] |
HUANG Bao-hua1,CHEN Rong1*,ZENG Hai-shan2,WANG Yue-yun1,XIE Shu-sen1 . The Impact of Blood Content in Skin Tissue on Skin Spectra[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27(01): 95-98. |
[5] |
LIU Guang, CHEN Bo, MENG Fan-bo, MA Hui*, CHEN Die-yan . Fluorescence Fluctuation Spectroscopy with Strong Background Fluorescence——An Monte Carlo Approach[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24(11): 1379-1383. |
|
|
|
|