光谱学与光谱分析 |
|
|
|
|
|
The Field Radiometric Calibration and Validation of ZY-3 Multispectral Sensor |
ZHANG Xue-wen, FU Qiao-yan, HAN Qi-jin*, PAN Zhi-qiang, YANG Lei |
China Center for Resources Satellite Data and Application,Beijing 100094,China |
|
|
Abstract A field calibration campaign of ZY-3 multispectral sensor (MUS) was performed by the China Center for Resources Satellite Data and Application at the Dunhuang site. The reflectance-based method with two-point sites was used to obtain MUS absolute calibration coefficients in 2013. Compared to the calibration results in 2012, the calibration coefficients in 2013 changed by about 1%~8.5% in different bands. The results were also validated by intercalibration method using the Landsat 8 Operational Land Imager (OLI) data. It shows largely good consistency between field calibration and intercalibration. It was concluded that the absolute calibration coefficients were highly reliable.
|
Received: 2013-10-24
Accepted: 2014-01-21
|
|
Corresponding Authors:
HAN Qi-jin
E-mail: cresda_hanjin@126.com
|
|
[1] Slater P N, Biggar S F, Holm R G, et al. Remote Sensing of Environment,1987, 22(1): 11. [2] Loeb N G. Int. J. Remote Sensing, 1997, 18(3): 477. [3] Kaufman Y J. IEEE Trans. Geosci. & Remote Sensing, 1988, 26(4). [4] Teillet P M, Markham B L, Richard R. Remote Sensing of Environment, 2006, 102: 264. [5] Thome K, LaMarr J, Scott K, et al. Proceedings of SPIE Volume 3439, Earth Observing Systems III, William L. Barnes, Editor, 1998. 439. [6] David Meyer, Gyanesh Chander. Proc. SPIE,2006, 6296:62960H. [7] Chen Zhengchao, Liu Xiang, Li Junsheng, et al. Journal of Astronautics,2008, 29(2): 638. [8] Fu Qiaoyan, Min Xiangjun, Li Xingchao, et al. Journal of Remote Sensing,2006,10(4): 433. [9] Yu Xiaolei, Wu Zhaocong. Chinese Journal of Sensors and Actuators. 2011,24(10): 1435. [10] Gong Hui, Tian Guoliang, Yu Tao, et al. Journal of Remote Sensing,2010,14(1): 7. [11] Biggar S F, Gellman D I, Slater N. Remote Sens Environ, 1990, 32: 91. [12] Liang Sunlin. Quantitative Remote Sensing. Beijing:Science Press, 2009. 146. |
[1] |
DONG Chao1, 2, ZHAO Geng-xing2*, SU Bao-wei2, CHEN Xiao-na2, ZHANG Su-ming2. Decision Model of Variable Nitrogen Fertilizer in Winter Wheat Returning Green Stage Based on UAV Multi-Spectral Images[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(11): 3599-3605. |
[2] |
ZHAO Xiao-yang1, 2, ZHANG Jian1, 2*, ZHANG Dong-yan3, ZHOU Xin-gen4, LIU Xiao-hui3, XIE Jing5*. Comparison between the Effects of Visible Light and Multispectral Sensor Based on Low-Altitude Remote Sensing Platform in the Evaluation of Rice Sheath Blight[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(04): 1192-1198. |
[3] |
GUO Jun-jie1, 2, 3, YAO Zhi-gang2, 3, 4*, HAN Zhi-gang2, 3, ZHAO Zeng-liang2, 3, YAN Wei1. Inter-Calibration for TG-2/MAI Visible Band Based on Metop-B/GOME-2[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(01): 56-64. |
[4] |
ZHOU Ke1, 2, 3, 5, LIU Li4*, YU Tao1, 3, GU Xing-fa1, 3, ZHENG Feng-bin5, ZANG Wen-qian1, 3. Sensitivity Analysis of Spectral Band Adjustment Factors For GF-1/WFV Sensor Cross-Calibration[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(12): 3809-3813. |
[5] |
XU Na1, 2, HU Xiu-qing1, 2*, CHEN Lin1, 2, ZHANG Yong1, 2 , HU Ju-yang1, 2, SUN Ling1, 2 . On-Orbit Radiometric Calibration Accuracy of FY-3A MERSI Thermal Infrared Channel[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(12): 3429-3434. |
[6] |
ZHOU Guan-hua1,2, JIANG He1,2, ZHAO Hui-jie1,2*, JIA Fei1,2 . Imaging Spectrometry Radiometric Cross-Calibration Based on Precise Spectral Response Matching [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(12): 3416-3421. |
[7] |
HU Xiu-qing1,2,LIU Jing-jing2,QIU Kang-mu2,FAN Tian-xi2,ZHANG Yu-xiang2,RONG Zhi-guo2,ZHANG Li-jun2 . New Method Study of Sites Vicarious Calibration for SZ-3/CMODIS[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29(05): 1153-1159. |
|
|
|
|