光谱学与光谱分析 |
|
|
|
|
|
The Optimizing Design and Experiment for a MOEMS Micro-Mirror Spectrometer |
MO Xiang-xia, WEN Zhi-yu, ZHANG Zhi-hai, GUO Yuan-jun |
National Key Laboratory of Fundamental Science of Micro/Nano-Device and System Technology, The Key Laboratory for Opto-Eletronic Technology and System under Ministry of Education, Chongqing University, Chongqing 400044 |
|
|
Abstract A MOEMS micro-mirror spectrometer, which uses micro-mirror as a light switch so that spectrum can be detected by a single detector, has the advantages of transforming DC into AC, applying Hadamard transform optics without additional template, high pixel resolution and low cost. In this spectrometer, the vital problem is the conflict between the scales of slit and the light intensity. Hence, in order to improve the resolution of this spectrometer, the present paper gives the analysis of the new effects caused by micro structure, and optimal values of the key factors. Firstly, the effects of diffraction limitation, spatial sample rate and curved slit image on the resolution of the spectrum were proposed. Then, the results were simulated; the key values were tested on the micro mirror spectrometer. Finally, taking all these three effects into account, this micro system was optimized. With a scale of 70 mm×130 mm, decreasing the height of the image at the plane of micro mirror can not diminish the influence of curved slit image in the spectrum; under the demand of spatial sample rate, the resolution must be twice over the pixel resolution; only if the width of the slit is 1.818 μm and the pixel resolution is 2.278 6 μm can the spectrometer have the best performance.
|
Received: 2010-12-25
Accepted: 2011-03-12
|
|
Corresponding Authors:
MO Xiang-xia
E-mail: yiyang.xx@hotmail.com;yiyang_3@163.com
|
|
[1] ZHANG Jun, CHEN Xing-dan, PIAO Ren-guan(张 军, 陈星旦, 朴仁官). Optics and Precision Engineering(光学精密工程), 2008, 16(6): 986. [2] ZHANG Bo, WEN Zhi-yu(张 波, 温志渝). Semiconductor Optical Electronics(半导体光电), 2007, 28(1): 147. [3] Kraft M, Kenda A, Frank A. Anal. Bioanal. Chem., 2006, 386: 1259. [4] Day D R, Butler M A, Smith M C. Transducers’ 05. The 13th International Conference on Volume 2, 2005. 1246. [5] CHEN Wei-min, HU Song, WEN Zhi-yu(陈伟民, 胡 松, 温志渝). Piezoelectrics & Acoustooptics(压电与声光), 2000, 22(3): 149. [6] Lü Nai-guang(吕乃光). Fourier Optis(傅里叶光学). Beijing: China Machine Press(北京:机械工业出版社), 2006. 92. [7] FENG Yu-tao, XIANG Yang(冯玉涛, 向 阳). Optics and Precision Engineering(光学精密工程), 2009, 17(1): 20. [8] WU Guo-an(吴国安). The Design of Spectrometer(光谱仪器设计). Beijing:Science Press(北京: 科学出版社), 1978. 104. |
[1] |
HU Wen-bin1, MA Zhi-min1*, TIAN Meng1, ZHAO Xiao-hong1, HU Xiang-yang2. Multispectral-Based Particle Image Velocimetry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(07): 2038-2043. |
[2] |
WANG Shuai1, XU Jun-ping1, WANG Nan1, LEI Wan-ying1, FAN Xi-yan1, DOU Sen2, 3*. Structural Characteristics of Mineral-Microbial Residues Formed by Microbial Utilization of Lignin Joined with Fe, Al, Mn-Oxides Based on FT-IR and SEM Techniques[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(07): 2086-2093. |
[3] |
LIU Ling1, YANG Ming-xing1, 2*, LU Ren1, Andy Shen1, HE Chong2. Study on EDXRF Method of Turquoise Composition[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(06): 1910-1916. |
[4] |
GAO Hao1, WANG Xiao1, SHANG Lin-wei1, ZHAO Yuan1, YIN Jian-hua1*, HUANG Bao-kun2*. Design and Application of Small NIR-Raman Spectrometer Based on Dichroic and Transmission Collimating[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(06): 1933-1937. |
[5] |
MA Yun-yun1, WANG Yong-qiang2, MIN Qi2, CAO Shi-quan2, ZHANG Zheng-rong1, SU Mao-gen2, SUN Dui-xiong2*, DONG Chen-zhong2. Relative Spectral Intensity Response Calibration of Spectrometers Using Ar Plasma Emission Branching Ratio Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(05): 1375-1379. |
[6] |
ZHANG Rui1,2, ZHU Ji-wei1, LIU Jian-li1,2, CUI Ji-cheng1, LI Xiao-tian1, Bayanheshig1. Study on the Laser-Induced Plasma Spectroscopy Based on the Echelle Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(05): 1605-1609. |
[7] |
YANG Xiu-da, ZHANG Ling*, XU Zong, ZHANG Peng-fei, CHEN Ying-jie, HUANG Juan, WU Zhen-wei,. In-situ Absolute Intensity Calibration of Fast-Response Extreme Ultraviolet Spectrometer on Experimental Advanced Superconducting Tokamak[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(04): 1262-1267. |
[8] |
ZOU Yao-pu1, 2, ZHANG Lei1, 2, HAN Chang-pei2*, LI Li-bing2. Study of High Accuracy Spectral Calibration of Fourier Transform Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(04): 1268-1275. |
[9] |
YUAN Jing, SHEN Jia-lin*, LIU Jian-kun, ZHENG Rong-hua. Determination of Rare Earth Elements in Geological Samples by High-Energy Polarized Energy-Dispersive X-Ray Fluorescence Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(02): 582-589. |
[10] |
HONG Guang-lie1, ZHOU Yan-bo1,2, LIU Hao1, KONG Wei1, SHU Rong1,2*. Feasibility Study of Mars Rover’s Laser Induced Breakdown Spectroscopy Based Mie-Lidar Design[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(02): 600-605. |
[11] |
YAN Zheng-zhou1,2,5, DENG Li-cai1, ZHANG Chun-guang1, LUO Chang-qing1, Grundahl F3, HU Zhong-wen4, JI Hang-xin4, WANG Jia-ning4, XU Ming-ming4, DAI Song-xing4, Andersen M F3, WANG Kun5, TIAN Jian-feng1. SONG-China Project High Resolution Spectrograph and High Precision Radial Velocity Measurements of Asteroseismology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(02): 621-626. |
[12] |
XING Li-feng1,2, CHANG Liang1,2. Lithium Abundance of 17 Young Nearby Stars: High Resolution Spectrograph Observation with Lijiang 1.8 m Telescope[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(12): 3900-3903. |
[13] |
TANG Qian1, GUO Li-xin1*, ZHAO Bao-chang2. An Allotype Double H-V Depolarizer for Hyperfine Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(12): 3913-3919. |
[14] |
LIU Xiang-lei1,2, LIU Yang-yang1*, FANG Yu1, PEI Lin-lin1, Lü Qun-bo1. Optical Design of Large Relief Large Relative Apertureand High Resolution Modified Dyson Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(12): 3908-3912. |
[15] |
GAO Jian-hua1,2, LIANG Jing-qiu1, Lü Jin-guang1*, LIANG Zhong-zhu1, QIN Yu-xin1, WANG Wei-biao1. A Stepped Mirror Based Temporally and Spatially Modulated Imaging Fourier Transform Spectrometer: Principle and Data Processing[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(12): 3932-3939. |
|
|
|
|