光谱学与光谱分析 |
|
|
|
|
|
The Analysis of the Sampling Modulation Transfer Function and the Influence on the Gaussian Spectra |
ZHAO Lie-feng,XU Zhi-hai*, FENG Hua-jun, LI Qi |
State Key Lab of Modern Optical Instrumentation,Zhejiang University, Hangzhou 310027, China |
|
|
Abstract As the parameters of the photoelectric detector have important effects on the performance of the dispersive spectrometers, it is necessary to detail the discrete sampling process of the photoelectric detector array. In the present paper, the sampling model was setup, and the effects on the sampling results caused by the spatial frequency of the cosine signal, the width of the sampling pixel, and the initial phase of the sampling pixel position to the crest of the input cosine signal were discussed thoroughly in the frequency domain. By introducing the integral function, a general expression of the sampling modulation transfer function was given, and the concept and expression of the average sampling modulation transfer function was proposed. Since that expression eliminates the effect of initial phase, it is much more convenient to the practical applications. For the typical Gaussian spectrum produced by the dispersive spectrometer, the Fourier transform result of that spectrum was multiplied by the average sampling modulation transfer function to produce a functional expression of the modulation transfer function of the whole system. The average aliasing error of the sampling process was expressed as a function of spatial frequencies; the relationship between the peak value of the average aliasing error and the width of the Gaussian spectrum was discussed; and the critical value of the spectrum width to restore this spectrum precisely was proposed. That critical value is significant for providing guidance to the design and fabrication of dispersive spectrometers.
|
Received: 2008-02-06
Accepted: 2008-05-08
|
|
Corresponding Authors:
XU Zhi-hai
E-mail: xuzh@zju.edu.cn
|
|
[1] ZHANG Zhan-xia, LIU Hong-tao, HE Jia-yao (张展霞, 刘洪涛, 何家耀). Spectroscopy and Spectral Analysis (光谱学与光谱分析), 2000, 20(2): 160. [2] HU Song, CHEN Wei-min, WEN Zhi-yu, et al(胡 松, 陈伟民, 温志渝, 等). Acta Optica Sinica(光学学报), 2002, 22(2): 190. [3] CHEN Gang, WEN Zhi-yu, WU Ying, et al (陈 刚, 温志渝, 吴 英, 等). Acta Photonica Sinica(光子学报), 2002, 31(3): 297. [4] YANG Huai-dong, XU Li, CHEN Ke-xin, et al(杨怀栋, 徐 立, 陈科新, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2005, 25(9): 1520. [5] Wittenstein W, Fontanella J C, Newbery A R, et al. Journal of Modern Optics, 1982, 29(1): 41. [6] Park S K, Schowengerdt R, Kaczynski M A. Applied Optics, 1984, 23(15): 2572. [7] Barnard K J, Boreman G D, Plogstedt A E, et al. Applied Optics, 1992, 31(1): 144. [8] Marchywka M, Socker D G. Applied Optics, 1992, 31(34): 7198. [9] Greivenkamp J E, Lowman A E. Applied Optics, 1994, 33(22): 5029. [10] Hu J, Song M, Sun Y, et al. Optical Engineering, 1999, 38(7): 1200. [11] Backman S M, Makynen A J. Optics Express, 2004, 12(12): 2610. [12] Pozo A M, Ferrero A, Rubino M, et al. Optics Express, 2006, 14(13): 5928. [13] Feltz J C, Karim M A. Applied Optics, 1990, 29(5): 717. [14] Feltz J C. Optical Engineering, 1990, 29(8): 893. [15] Friedenberg A. Optical Engineering, 1996, 35(7): 2105. |
[1] |
LIANG Zhen-jiang, LIU Hai-xia*, LIU Kai-ming, NIU Yan-xiong, YIN Yi-heng . The Analysis of Microcavity-Integrated Graphene Photodetector’s SNR Based on 1.06 μm [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(02): 356-360. |
[2] |
QIAN Lu-lu1, 2, XIANGLI Bin1, 2, Lü Qun-bo2*, ZHOU Zhi-liang2,FU Qiang2 . Imaging Quality Evaluation of Computational Imaging Spectrometry [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(07): 1987-1991. |
[3] |
LIU Hong-xing1,2 , REN Jian-wei1, WAN Zhi1, LIU Ze-xun1, LI Bao-yong1, YE Zhao1,2 . Measurement of Relative Spectral Responsivity of Photodetector by LED-Based Spectrum-Tunable Source [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(01): 250-254. |
[4] |
ZHAI Yang1,ZHU Ri-hong1*,SHEN Hua1,GU Jin-liang2 . Influence of Laser Power and Incident Angle as well as Testing Distance on Laser Inducted Breakdown Spectroscopy (LIBS) Technology for Spectroscopy Diagnosis and Multi-Element Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(10): 2634-2638. |
[5] |
CHENG Xin1,2,WANG Jing1*,ZHANG Bao1,HONG Yong-feng1 . Effect of Spectrum Distortion on Modulation Transfer Function in Imaging Fiber-Optic Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(10): 2861-2864. |
[6] |
ZHAI Yang1,SHEN Hua1,ZHU Ri-hong1*,MA Suo-dong1,LI Jian-xin1,CHEN Lei1,GU Jin-liang2 . Development of Transient Pyrometer Based on Multi-Spectral Radiation Technology [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30(11): 3161-3165. |
[7] |
WANG Chun-hong1, 2, 3,XIANG Yang1* . MTF of Line-Array CCD on Detection Performance for Hyperspectral Imager[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29(06): 1478-1481. |
[8] |
YANG Huai-dong, XU Li, CHEN Ke-xin, HE Qing-sheng, HE Shu-rong, TAN Qiao-feng, JIN Guo-fan. The Effect of the Photoelectric Detector on the Accuracy of the Spectrometer [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(09): 1520-1523. |
|
|
|
|