光谱学与光谱分析 |
|
|
|
|
|
Determination of Aluminum in Sediments by Atomic Absorption Spectrophotometer without FIA Spectrophotometric Analysis |
ZHAO Zhen-yi,HAN Guang-xi,SONG Xi-ming,LUO Zhi-xiong |
Chemistry Institute of Science and Engineering, Liaoning University, Shenyang 110036, China |
|
|
Abstract To search for a new method of determining, we developed a new flow injection analyzer, applied to the atomic absorption spectrophotometer, relying on it without flame in place of visible spectrophotometer, and studied the appropriate condition for the determination of aluminum in sediments, thus built up a kind of new analytical test technique. Three peak and two valley absorption values (A1, A2, A3, A4 and A5) can be continuously obtained simultaneously that all can be used for quantitative analysis, then we discussed its theory and experiment technique. Based on the additivity of absorbance (A=A1+A2+A3+A4+A5), the sensitivity of FIA is enhanced, and its precision and linear relation are also good, raising the efficiency of AAS. The simple method has been applied to determining Al in sediments, and the results are satisfactory.
|
Received: 2006-12-10
Accepted: 2007-03-20
|
|
Corresponding Authors:
ZHAO Zhen-yi
E-mail: sophie0725@126.com
|
|
[1] Perez-Ruiz T, Martimez-Lozamoc, Tomas V, et al. Microchemica Acta, 2003, 141(2): 3. [2] SUN Li-jing, FANG Zhao-lun(孙励敬, 方肇伦). Analytical Chemistry(分析化学), 1981, 9: 586. [3] Fang Z L, Ruzicka J, Hansan E H. Anal. Chim. Acta, 1984, 164: 23. [4] Jabes A B, Andrew W B. Anal. Chem., 1980, 52(7): 1054. [5] ZHAO Zhen-yi, CHEN Hua(赵珍义,陈 华). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 1998, 18(1): 124. [6] ZHAO Zhen-yi(赵珍义). Journal of Instrumental Analysis(分析测试学报), 1997, 16(5): 32. [7] WU Zhi-hao, LI Gui-min, WANG Jin-zhong, et al(吴志皓,李桂敏,王金中,等). Physical Testing and Chemical Analysis, Part B: Chemical Analysis(理化检验—化学分册), 2006, 42(3): 227.
|
[1] |
ZHENG Pei-chao, ZHONG Chao, WANG Jin-mei*, LUO Yuan-jiang, LAI Chun-hong, WANG Xiao-fa, MAO Xue-feng. Evaluation of Flow Injection-Solution Cathode Glow Discharge With an Interference Filter Wheel for Spectral Discrimination[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(03): 842-847. |
[2] |
AN Xue-jing, LUO Yun-jing*, ZHANG Chen-yang. Research on the Reaction Dynamics between Peroxynitrite and Tyrosine Catalyzed with Mimic Enzyme through Flow Injection Analyzer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(12): 4052-4057. |
[3] |
HAN Bin1, CAO Lei1, 2, ZHENG Li1, ZANG Jia-ye1, WANG Xiao-ru1 . Flow Injection-Spectrophotometric Determination of Total Dissolved Nitrogen in Seawater Based on Quantificational Solenoid Valves[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(01): 219-222. |
[4] |
MI Jian-ping1,LI Yuan-qian1*,ZOU Xiao-li1,ZHENG Bo1,YANG Jing-guo2 . Simultaneous Determination of Iron, Copper and Cobalt in Food Samples by Diode Array Detection-Flow Injection Analysis Using Partial Least Squares Calibration Model [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27(06): 1188-1191. |
[5] |
LI Yuan-qian1, Lü Xing1, ZOU Xiao-li1, MI Jian-ping1, YANG Jing-guo2 . CCD-Array Detection-Flow Injection Analysis of Oligomeric Proanthocyanidins in Health Food[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(10): 1724-1726. |
[6] |
MA Hong-yan. Determination of Genyamicin Sulfate in Injections by Flow-Injection Electrogenerated Chemiluminescence [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(08): 1210-1212. |
[7] |
FAN Jing, Lü Hui-xiong, YE Cun-ling,CUI Feng-ling. Speciation Analysis of Selenium by Flow-Injection Catalytic Spectrophotometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(02): 263-265. |
[8] |
GUO Liang-qia, XIE Zeng-hong*, LIN Xu-cong, KE Zi-hou, CHEN Guo-nan . Direct Fluorophotometric and Flow-Injection Fluorophotometric Methods for the Determination of Trace Ammonia [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24(07): 851-854. |
|
|
|
|