Raman Spectroscopy-Encoded Fluorescence Suspension Array Detection System |
XIE Lu-yuan1, GUAN Tian1*, HE Yong-hong2*, HOU Jian-xun3, XU Tao4, CHEN Xue-jing2, WANG Bei2, SHEN Zhi-yuan2, XU Yang2 |
1. Department of Biomedical Engineering, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
2. Laboratory of Optical Imaging and Sensing, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
3. Shenzhen Institute for Drug Control (Shenzhen Testing Center of Medical Devices), Shenzhen 518057, China
4. Shenzhen Academy of Metrology & Quality Inspection, Shenzhen 518055, China |
|
|
Abstract With the increasing demands for medical diagnosis, more and more attention has been paid to the technology of biomolecular detection. As a high throughput and multiplexed molecular detection method, suspension array has developed rapidly in recent years. In this study, a Raman spectra-encoded suspension array with micro-quartz pieces as the carrier was prepared by the layer-by-layer self-assembly method, and a high sensitivity and high resolution optical system was built to realize the qualitative and quantitative analysis of the suspension array. The home-built optical system was obtained by coupling Raman spectroscope with a fluorescence microscope. For the Raman spectroscope, a 785 nm laser was converged on the sample through dichroic mirrors, reflector and object lens. Then the Raman scattering light produced by the sample passed through the objective lens, anti-reflection mirror, dichroic mirror and Raman filter, and focused on the slit of the spectrometer via the concave lens. And finally, Raman spectra can be obtained by the dispersion effect of the spectrometer. For the fluorescence microscope, which used the optical imaging principle, the excitation light could irradiate the sample uniformly through the objective lens by adjusting the distance between the concave lens and the excited light of 405 nm. Then, the emitted fluorescence passed through an objective lens, an anti-reflection mirror, dichroic mirror, a filter and a concave lens, and finally imaged on the matrix CCD. The coupling of the Raman spectroscope and the fluorescence microscope was completed by improving the optical path of the conventional portable Raman spectroscope and selecting the anti-reflecting mirror with the specific band and the objective lens with a focal length of 20×. In order to reduce the interaction between the Raman spectroscope and the fluorescence microscope, the appropriate dichroic mirror and filter were selected to improve the coupling system. The Raman spectra of the suspension array were detected by home-built system to accomplish the qualitative identification of each encoded micro-quartz pieces. At the same time, the fluorescence of the encoded micro-quartz pieces was excited and the fluorescence signal was collected to complete the quantitative analysis of the target analyst according to the fluorescence intensity value on each encoded micro-quartz pieces. Compared with traditional fluorescence-encoded suspension arrays, Raman spectra encoding method has the advantages of stronger stability and higher spectral resolution. This optical system integrates Raman spectroscope and fluorescence microscope, which solves the problem that there is no suspension array detection system based on Raman encoding method at present and can qualitatively and quantitatively analyze a variety of target molecules at the same time, improving the accuracy of the experimental results.
|
Received: 2018-06-25
Accepted: 2018-11-09
|
|
Corresponding Authors:
GUAN Tian, HE Yong-hong
E-mail: heyh@sz.tsinghua.edu.cn;guantian@sz.tsinghua.edu.cn
|
|
[1] Leng Y, Sun K, Chen X, et al. Chemical Society Reviews, 2015, 44(15): 5552.
[2] Shen Z Y, He Y H, Zhang G, et al. Optics Letters, 2018, 43(4): 739.
[3] Battersby B J, Lawrie G A, Trau M. Drug Discovery Today, 2001, 6(12): 19.
[4] Edwards B S, Oprea T, Prossnitz E R, et al. Current Opinion in Chemical Biology, 2004, 8(4): 392.
[5] Zhao Y, Zhao X, Pei X, et al. Analytica Chimica Acta, 2009, 633(1): 103.
[6] Deng S N, Liu L, Liu Z Y, et al. Applied Optics, 2012, 51(17): 3701.
[7] Kneipp K, Wang Y, Kneipp H, et al. Physical Review Letters, 1997, 78(9): 1667.
[8] Michaels A M, Jiang J, Brus L. Journal of Physical Chemistry B, 2013, 104(50): 11965.
[9] He Q H, Li D M, He Y H, et al. Journal of Biomedical Optics, 2017, 22(9).
[10] AN Yan, SUN Qiang, PIAO Ren-guan, et al(安 岩,孙 强,朴仁官,等). Laser & Optoelectronics Progress(激光与光电子学进展), 2012, 49.
[11] AN Yan, LIU Ying, SUN Qiang, et al(安 岩,刘 英,孙 强,等). Acta Optica Sinica(光学学报), 2013, 33(3).
[12] XIE Yin-zhong, ZHUANG Song-lin, ZHANG Bao-zhou(谢印忠,庄松林,张保洲). Chinese Journal of Scientific Instrument(仪器仪表学报), 2011, 32(3): 546.
[13] YANG Guang-lie(杨广烈). Optical Instruments(光学仪器), 2001, 23(2): 20.
[14] LU Shu-hua, WANG Yin-shu(卢树华, 王引书). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2018, 38(5): 1412.
[15] He Q H, Liu Y X, He Y H. Scientific Reports, 2016, 6: 36511. |
[1] |
ZHANG Nan-nan1, 3, CHEN Xi-ya1,CHANG Xin-fang1, XING Jian1, GUO Jia-bo1, CUI Shuang-long1*, LIU Yi-tong2*, LIU Zhi-jun1. Distributed Design of Optical System for Multi-Spectral Temperature
Pyrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 230-233. |
[2] |
TIAN Peng1, XIAO Xue-song1, SU Gui-tian1, DUAN Han-feng1,JIN Yao-dong1, SONG Yang-yang1, HUANG Tao2, ZHANG Hang1*. Fluorescence Spectra Analysis of N-n-Octyl Oyridine Acetate Ionic Liquid in Different Solvents[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(01): 147-151. |
[3] |
WU Xin1,2, LI Guang-lin1*, WEN Zhi-yu3. Study and Determination of Nitriding Salt with Salt Bath Heat Treatment Technology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(11): 3347-3353. |
[4] |
ZHAO Wen-cheng, XU Xian-ze*, LIU Pan-pan, CHENG Wen-qiang, XU Feng-qiu . The Laser Rangefinder System in Quadrature Modem and Ambiguity Resolution[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(02): 659-664. |
[5] |
CHEN Wei-kang1, FANG Hui2* . Particle Size and Number Density Online Analysis for Particle Suspension with Polarization-Differentiation Elastic Light Scattering Spectroscopy [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(03): 770-774. |
[6] |
ZHANG Hua1,2, WANG Kuan1,2, SONG Jian1,2*, ZHANG Yong1,2, HUANG Ming1,2, HUANG Jian1,2, ZHU Jing1,2, HUANG Shan1,2, WANG Meng1,2. The Fluorescent Properties of Dissolved Organic Matter and Assessment of Total Nitrogen in Overlying Water with Different Dissolved Oxygen Conditions[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(03): 890-895. |
[7] |
HE Xiao1,3, ZHANG Li-sheng2, ZU En-dong1*, YANG Xiao-yun3, DONG Kun3 . Research on the Relationship between Surface Structure and Fluorescence Intensity of Ca(1-x)Al2Si2O8∶Eux [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(01): 146-150. |
[8] |
LIU Yan-zhou, YANG Yan-min*, GUO Yan-ming, ZHANG Lian-shui, MI Chao, LIU Lin-lin . Er3+∶Yb3+ Co-Doped Nanocrystals BaGd2ZnO5 of Up-Conversion Optical Temperature Sensing [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(02): 329-333. |
[9] |
TAO Dong-liang1,2,3, LI Hui-zhen4, CUI Yu-min1,3, JIA Ya-li4, LIU Shao-xuan2, XU Yi-zhuang2*, WANG Yong-zhong1, CHEN Ji-tang1, SHI Rui-juan1,3, ZHANG Wen-bao1, QIAO Xue-ling1, SUN Wen-zhong1, ZHANG Hong1 . Study on Preparations and Fluorescent Properties of Rare Earth Complex with Property of Fluorescence Sensor [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(09): 2473-2476. |
[10] |
CHEN Xiao-bo, CHEN Ying, LI Song*, YAO Wen-ting, WU Zheng-long . The Changing Process of Population Probability and Fluorescence Intensity in ErP5O14 Noncrystalline from 0 Second to Stabilization [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(06): 1490-1495. |
[11] |
YU Hai-bin1, WANG Ye-yao2*, SONG Cun-yi1 . Study of Three-Dimensional Fluorescence Spectra for Measuring Chlorobenzene in Water[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(07): 1823-1827. |
[12] |
ZHANG Ying, ZHAO Hui-jie, CHENG Xuan, XIONG Sheng-jun . Design of Full-Polarized and Multi-Spectral Imaging System Based on LCVR [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(05): 1375-1378. |
[13] |
Lü Qun-bo1, XIANGLI Bin1, 2*, YAO Tao1, 3, JING Juan-juan1, WANG Zhong-hou1 . Modeling and Simulation of Effect of Optical Distortion on the Large Aperture Static Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30(01): 142-145. |
[14] |
JIN Dan1, ZHANG Yu-jun1*, LI Guo-gang2, XIAO Xue1, WANG Zhi-gang1, 3, YIN Gao-fang1, LIU Wen-qing1 . Study on Three-Dimensional Fluorescence Spectra of Phenanthrene[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29(05): 1319-1322. |
[15] |
LING Xiao,BORJIHAN Ge-rel-tu*,ZHOU Hai-jun,NA Ri-su. Fluorescence Characteristics and Analytical Application of Mn(Ⅱ)-Piperine-Cetyltrimethylammonium Bromide Ternary System[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29(01): 188-191. |
|
|
|
|