|
|
|
|
|
|
Full State-Resolved Rotational Distribution of CO2 in Collisions with Highly Vibrationally Excited K2 |
WANG Shu-ying, DAI Kang, SHEN Yi-fan |
School of Physics Science and Technology, Xinjiang University, Urumqi 830046, China |
|
|
Abstract Highly vibrationally excited K2(E=3 500 and 4 000 cm-1) was achieved by stimulated emission pumping. The full state-resolved distribution of scattered CO2(0000) molecules from collisions with excited K2(E) was reported. The donor energy dependence for full J-state distribution of energy upstate in collisions has been investigated. Nascent rotational and translational energy profiles for scattered CO2(0000) molecules with J=2~74 were measured using high resolution transient laser induced fluorescence (LIF). The appearance line widths were obtained by fitting the double Gaussian function to the transient line profile data at t=1 μs. Doppler-broadened line widths and the relative (center of mass frame) translational temperatures for appearance and depletion of scattered CO2 molecules, the lab-frame translational temperatures and average translation energy of appearance section for K2(E)/CO2 collisions were determined. The energy transfer mechanism was similar at both donor energies, which was vibration-rotation/translation relaxation mechanism. But collisonal appearance temperatures were beyond the pool temperature, while collisonal depletion temperatures were slightly lower than the pool temperature, and the magnitude of energy transferred into translational energy increased with donor energy. The donor vibrational energy going into translational energy of the collision products was strongly dependent on the initial energy. The translational energy of the J-specific collision products increased by 40% or more for a 14% increase in donor vibrational energy. The nascent rotational distribution of scattered CO2(0000) molecules was shown for collisions with K2(E=3 500 cm-1). The semilog plot showed evidence of a biexponential distribution. A better description of the nascent rotational distribution came from fitting with the sum of two independent distributions. The fitting yielded a low-energy distribution with Ta=(523±60) K and a high energy distribution with Tb=(1 890±210) K. The proximity of Ta to the initial 553 K distribution showed that nearly elastic collisions populated the low J final states, which belong to single quantum relaxation processes. In contrast, the strong collisions that were responsible for the high energy tail were inelastic and involved large increases in J, which belonged to multi-quantum relaxation processes. The full J-state rotational distribution of CO2 from collisions with K2(E=4 000 cm-1) also showed biexponential behavior. Biexponential fitted results in Ta=(620±65) K and Tb=(2 240±250) K. Each of these values at E=3 500 cm-1 was approximately 19% greater than for corresponding values at E=3 500 cm-1. Thus, the highly energy donor molecules imparted more rotational energy for the full range of bath rotational states. The spread of the rotational distribution was sensitive to K2 difference energy, but the branching ratio for elastic and inelastic collisionswas the same The weak collision pathway accounted for ~82% of collisions with CO2(0000) products, while the strong collision pathway accounted for ~18%.
|
Received: 2017-02-17
Accepted: 2017-05-22
|
|
|
[1] Es-sebbar E, Deli M, Farooq A. Appl. Spectrosc., 2016, 70(6): 972.
[2] Shen X Y, Wang S Y, Dai K, et al. Spectrochim. Acta A, 2017, 173: 516.
[3] Yang B H, Balakrishnan N, Zhang P, et al. J. Chem. Phys., 2016, 145: 034308.
[4] Jankowski P, Surin L A, Potapov A, et al. J. Chem. Phys., 2013, 138: 084307.
[5] Li H, Zhang X L, Le Roy R J, et al. J. Chem. Phys., 2013, 139: 164315.
[6] McCaffery A J. J. Chem. Phys., 2015, 143: 104306.
[7] Unke O T, Castro-Palacio J C, Bemish R J, et al. J. Chem. Phys., 2016, 144: 224307.
[8] Tong X, Nagy T, Reyes J Y, et al. Chem. Phys. Lett., 2012, 547: 1.
[9] Du J, Yuan L W, Hsieh S, et al. J. Phys. Chem. A, 2008, 112(39): 9396.
[10] McCaffery A J. J. Chem. Phys., 2016, 144: 194304.
[11] Havey D K, Du J, Liu Q, et al. J. Phys. Chem. A, 2010, 114(3): 1569.
[12] Du J, Sassin N A, Havey D K, et al. J. Phys. Chem. A, 2013, 117(46): 12104.
[13] Mu B X, Cui X H, Shen Y F, et al. Spectroch. Acta A, 2015, 148: 299.
[14] Alghazi A, Liu J, Dai K, et al. Chem. Phys., 2015, 448: 76.
[15] WANG Shu-ying, ZHANG Wen-jun, DAI Kang, et al(王淑英,张文军,戴 康,等). Chin. J. Lasers(中国激光), 2015, 42(4): 225. |
[1] |
WANG Yu1, 2, ZHANG Xian-ke1, 2, TAN Tu1, WANG Gui-shi1, LIU Kun1, SUN Wan-qi3*, QIU Zi-chen4, GAO Xiao-ming1, 2. Research on Moving Observation of Typical Greenhouse Gas Sources in Hefei by Using Off-Axis Integrated Cavity[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(10): 3293-3301. |
[2] |
YUAN Kai-xin, ZHUO Jin, ZHANG Qing-hua, LI Ya-guo*. Study on the Spectral and Laser Damage Resistance of CO2 Laser Modified Sol-Gel SiO2 Thin Films[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1752-1759. |
[3] |
WANG Shu-ying*, YOU De-chang, MA Wen-jia, YANG Ruo-fan, ZHANG Yang-zhi, YU Zi-lei, ZHAO Xiao-fang, SHEN Yi-fan. Experimental Collisional Energy Transfer Distributions for Collisions of CO2 With Highly Vibrationally Excited Na2[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1760-1764. |
[4] |
WANG Mei-li1, 2, SHI Guang-hai2*, ZHANG Xiao-hui1, YANG Ze-yu2, 3, XING Ying-mei1. Experimental Study on High-Temperature Phase Transformation of Calcite[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(04): 1205-1211. |
[5] |
DU Bao-lu, LI Meng, GUO Jin-jia*, ZHANG Zhi-hao, YE Wang-quan, ZHENG Rong-er. The Experimental Research on In-Situ Detection for Dissolved CO2 in
Seawater Based on Tunable Diode Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(04): 1264-1269. |
[6] |
YE Han-han, WANG Xian-hua, LI Qin-qin, WANG Xiao-di. Correction the Effect of Plant Chlorophyll Fluorescence on Atmospheric Carbon Dioxide Satellite Monitoring[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(02): 368-371. |
[7] |
HONG Guang-lie1, LIANG Xin-dong1, 2, LIU Hao1*, ZHANG Hua-ping1, 2, SHU Rong1, 2. Detection of CO2 Average Concentration in Atmospheric Path by CW Modulated Differential Absorption Lidar[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(12): 3653-3658. |
[8] |
LI Jin-yi1, FAN Hong-qing1, TIAN Xin-li1, LI Hong-lian2, WU Zhi-chao1, SONG Li-mei1. Pressure Correction for Calibration-Free Measurement of Wavelength Modulation Spectroscopy in Atmospheric Environment[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(05): 1407-1412. |
[9] |
WU Hong-peng1, 2*, PENG Sai-nan1, ZHAO Jin-biao1, DONG Lei1, 2*, JIA Suo-tang1, 2. Research on High Sensitive Detection of CO2 Gas Based on Power-Boosted QEPAS Technology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(03): 840-844. |
[10] |
WANG Fei1,2, LI Huan1, CRESSAULT Yann2, TEULET Philippe2, YANG Ke1. Net Emission Coefficients for [82%Ar-18%CO2]-Fe Plasmas in Welding Arcs[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(07): 2010-2015. |
[11] |
LI Zheng-hui1,3, YAO Shun-chun1,3*, LU Wei-ye2, ZHU Xiao-rui1,3, ZOU Li-chang1,3, LI Yue-sheng2, LU Zhi-min1,3. Study on Temperature Correction Method of CO2 Measurement by TDLAS[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(07): 2048-2053. |
[12] |
MA Hui1, 2, LIU Dong1*, LI Wen-feng3, LIAO He3, XIE Chen-bo1, WANG Zhen-zhu1, WANG Bang-xin1, HUANG Jian1, WANG Ying-jian1, 2*. A Rapid and Accurate Optimizing Algorithm for IPDA Lidar Data Inversion[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(04): 1014-1018. |
[13] |
JIANG Yun1,2, YE Han-han1*, WANG Xian-hua1, DUAN Feng-hua1,2, WU Hao1,2. Influence of Chlorophyll Fluorescence on the Retrieval Accuracy of Carbon Dioxide[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(03): 864-868. |
[14] |
LIU Jing, DAI Kang, SHEN Yi-fan. Resonent Vibration-Vibration Energy Transfer Between Vibrationally Excited HBr (Χ1Σ+ ν″=5) and H2, N2, CO2, and HBr[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(10): 3000-3005. |
[15] |
LI Jia-jia1, LI Rong-xi1*, DONG Hui2, WANG Zhi-hai2, ZHAO Bang-sheng1, CHENG Jing-hua1. Quantitative Approach to Determination of δ13C Value of CO2 with Micro-Laser Raman Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(04): 1139-1144. |
|
|
|
|