光谱学与光谱分析 |
|
|
|
|
|
Solution Cathode Glow Discharge Based on Charge Coupled Device Detector |
LIU Xiao, YANG Xiao-tao, ZHAN Xiu-chun*, YUAN Ji-hai, FAN Xing-tao, JIAO Ju |
National Research Center for Geoanalysis, Beijing 100037, China |
|
|
Abstract In 21st century, many countries pay much attention to lithium because lithium is an ideal material for green energy and light alloys as well as an important kind of strategic resources. The main source of lithium is from salt lake brine. China has rich resources of salt lake brine, but these brine resources are mainly distributed in the remote western region, which are in urgent need of portable analytical instrument for on-site exploration and exploitation. However, the available experimental techniques at present can not achieve the target of on-site analysis. Over the past decade, based on atmospheric pressure solution cathode glow discharge-atomic emission spectrometry (SCGD-AES) has been paid attention to analytical researchers because it runs without common air conditions such as fuel gas, carrier gas and vacuum environment. On the basis of previous studies of other researchers, we have developed a portable SCGD based on a charge coupled device (CCD) detector by ourselves, which is short for Li-K analyzer. The length, width, height and weight of the portable Li-K analyzer is 35 cm, 19 cm, 27 cm and 10 kg, respectively, which is very conducive to carry. This work selected the wavelength of 670.78 nm as the characteristic spectral line of Li and has established a rapid analytical method for Li in salt lake brine based on two different types of brines from Tibet. Under the optimum operating conditions, the detection limit of Li was 4 ng·mL-1 and the measured precision (RSD) was better than 2%. The analytical results of Li were much different from those obtained by inductively coupled plasma-mass spectrometry (ICP-MS) with different dilution ratios by standard curve method, which may be related to the matrix effect of solution. However, the analytical results of Li agreed well with the results obtained by ICP-MS using standard addition method, which showed that standard addition method can effectively reduce the matrix effect and improve the analytical accuracies. A great deal of experimental results showed that standard addition method could obtain accurate results of Li using only two points and can greatly reduce the workloads. This work laid a methodological foundation for on-site determination of Li in salt lake brine by the portable Li-K analyzer.
|
Received: 2016-05-12
Accepted: 2016-10-20
|
|
Corresponding Authors:
ZHAN Xiu-chun
E-mail: zhanxiuchun2012@126.com
|
|
[1] LI Jian-kang, LIU Xi-fang, WANG Deng-hong. Acta Geologica Sinica, 2014,(12): 2269. [2] GAO Feng, ZHENG Mian-ping, NIE Zhen, et al. Acta Geoscientica Sinica, 2011, 32(4): 483. [3] NIE Zhen, BU Ling-zhong, ZHENG Mian-ping. Acta Geoscientica Sinica, 2010, 31(1): 95. [4] YUAN Hong-zhan, ZHU Yun-jun, WU Li-ping, et al. Rock and Mineral Analysis, 2011, 30(1): 87. [5] Zhu Chengcai, Dong Yaping, Yun Zeng, et al. Hydrometallury, 2014, 143. [6] Taddia M, Modesti P, Albertazzi A. Journal of Nuclear Materials, 2005, 336: 173. [7] ZHANG Zhen, WANG Zheng, ZOU Hui-jun, et al. Chinese Journal of Analytical Chemistry, 2013, 41(10): 1606. [8] GAI Rong-yin, WANG Zheng, HE Yan-feng, et al. Chinese Journal of Analytical Chemistry, 2014, (11): 1617. [9] Wang Z, Schwartz S, Ray S J, et al. Journal of Analytical Atomic Spectrometry, 2013, 28: 234. [10] Cserfalvi T, Mezei P. Fresenius Journal of Analytical Chemistry, 1996, 355(7-8): 813. [11] Grgy K, Bencs L, Mezei P, et al. Spectrochimica Acta Part B: Atomic Spectroscopy, 2012, 77: 52. [12] ZHENG Pei-chao, ZHANG Bin, WANG Jin-mei, et al. Spectmscopy and Spectral Amlysis, 2015, 35(7): 2012. [13] JIAO Ju, YANG Xiao-tao, ZHAN Xiu-chun, et al. Rock and Mineral Analysis, 2016, 35(4): 350. [14] Wang Z,Gai R Y,Zhou L,et al. Journal of Analytical Atomic Spectrometry, 2014, 29: 2042. [15] Wuhan University. Analytical Chemistry (Fifth Edition). Beijing: Higher Education Press, 2007, 11. |
[1] |
ZHANG Jing, GUO Zhen, WANG Si-hua, YUE Ming-hui, ZHANG Shan-shan, PENG Hui-hui, YIN Xiang, DU Juan*, MA Cheng-ye*. Comparison of Methods for Water Content in Rice by Portable Near-Infrared and Visible Light Spectrometers[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(07): 2059-2066. |
[2] |
HU Shuang1, LIU Cui-mei2*, XU Lin3, JIA Wei2, HUA Zhen-dong2. Rapid Qualitative Analysis of Synthetic Cathinones by Raman
Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1821-1828. |
[3] |
HU Shuang1, LIU Cui-mei2*, JIA Wei2, HUA Zhen-dong2. Rapid Qualitative Analysis of Synthetic Cannabinoids by Raman
Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(01): 145-150. |
[4] |
HAO Jun1, WANG Yu2, LIU Cong2, WU Zan2, SHAO Peng2, ZU Wen-chuan2*. Application of Solution Cathode Glow Discharge-Atomic Emission Spectrometry for the Rapid Determination of Calcium in Milk[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(12): 3797-3801. |
[5] |
TANG Ju1, 2, DAI Zi-yun2*, LI Xin-yu2, SUN Zheng-hai1*. Investigation and Research on the Characteristics of Heavy Metal Pollution in Children’s Sandpits Based on XRF Detection[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(12): 3879-3882. |
[6] |
FU Hong-bo1, WU Bian1, WANG Hua-dong1, ZHANG Meng-yang1, 2, ZHANG Zhi-rong1, 2*. Quantitative Analysis of Li in Lithium Ores Based on Laser-Induced Breakdown Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(11): 3489-3493. |
[7] |
YANG Qiao-ling1, 2, CHEN Qin2, NIU Bing2, DENG Xiao-jun3*, MA Jin-ge3, GU Shu-qing3, YU Yong-ai4, GUO De-hua3, ZHANG Feng5. Visualization of Thiourea in Bulk Milk Powder Based on Portable Raman Hyperspectral Imaging Technology On-Site Rapid Detection Method
Research[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(07): 2156-2162. |
[8] |
GUO Jin-ke, LU Ji-long, SI Jun-shi, ZHAO Wei, LIU Yang, WANG Tian-xin, LAI Ya-wen*. Study on Heavy Metal in Soil by Portable X-Ray Fluorescence
Spectrometry Based on Matrix Effect Correction and
Correspondence Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(07): 2309-2314. |
[9] |
LI Jia-yi1, YU Mei1, LI Mai-quan1, ZHENG Yu2*, LI Pao1, 3*. Nondestructive Identification of Different Chrysanthemum Varieties Based on Near-Infrared Spectroscopy and Pattern Recognition Methods[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(04): 1129-1133. |
[10] |
ZHANG Xiao-hong1, JIANG Xue-song1*, SHEN Fei2*, JIANG Hong-zhe1, ZHOU Hong-ping1, HE Xue-ming2, JIANG Dian-cheng1, ZHANG Yi3. Design of Portable Flour Quality Safety Detector Based on Diffuse
Transmission Near-Infrared Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(04): 1235-1242. |
[11] |
ZHANG Chen-ling, JIA Na*, LIU Jia, LIU Bing-bing, HAN Mei. Investigation of Lithium Analysis in Geothermal Water by Inductively Coupled Plasma Optical Emission Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(12): 3876-3880. |
[12] |
WAN Shun-kuan1, 2, LÜ Bo1, ZHANG Hong-ming1*, HE Liang1, FU Jia1, JI Hua-jian3, WANG Fu-di1, BIN Bin1, LI Yi-chao1, 2. Quick Measurement Method of Condensation Point of Diesel Based on Temperature-Compensation Model[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(10): 3111-3116. |
[13] |
ZHANG Bin-bin1, 2, LI Jing-bin1, 2, WANG Shi-ning1, 2, HE Peng-fei1, 2, ZHA Xiao-qin1, 2, 3. Determination of Lithium, Iron and Phosphorus in Carbon Composite Lithium Iron Phosphate by Perchloric Acid Digestion-Inductively Coupled Plasma Optical Emission Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(09): 2703-2709. |
[14] |
MA Jin-ge1, YANG Qiao-ling2, DENG Xiao-jun1*, SHI Yi-yin1, GU Shu-qing1, ZHAO Chao-min1, YU Yong-ai3, ZHANG Feng4. On-Site Rapid and Non-Destructive Identification Method for Imported Bulk Olive Oil Quality Based on Portable Raman Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(09): 2789-2794. |
[15] |
WANG Cong1, Mara Camaiti2, TIE Fu-de1,3, ZHAO Xi-chen4, CAO Yi-jian5*. Preliminary Study on the Non-Invasive Characterization of Organic Binding Media Employing a Portable Hyperspectral Sensor[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(09): 2886-2891. |
|
|
|
|