光谱学与光谱分析 |
|
|
|
|
|
Laser-Based Radiometric Calibration |
LI Zhi-gang, ZHENG Yu-quan |
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China |
|
|
Abstract Increasingly higher demands are put forward to spectral radiometric calibration accuracy and the development of new tunable laser based spectral radiometric calibration technology is promoted, along with the development of studies of terrestrial remote sensing, aeronautical and astronautical remote sensing, plasma physics, quantitative spectroscopy, etc. Internationally a number of national metrology scientific research institutes have built tunable laser based spectral radiometric calibration facilities in succession, which are traceable to cryogenic radiometers and have low uncertainties for spectral responsivity calibration and characterization of detectors and remote sensing instruments in the UK, the USA, Germany, etc. Among them, the facility for spectral irradiance and radiance responsivity calibrations using uniform sources (SIRCCUS) at the National Institute of Standards and Technology (NIST) in the USA and the Tunable Lasers in Photometry (TULIP) facility at the Physikalisch-Technische Bundesanstalt (PTB) in Germany have more representatives. Compared with lamp-monochromator systems, laser based spectral radiometric calibrations have many advantages, such as narrow spectral bandwidth, high wavelength accuracy, low calibration uncertainty and so on for radiometric calibration applications. In this paper, the development of laser-based spectral radiometric calibration and structures and performances of laser-based radiometric calibration facilities represented by the National Physical Laboratory (NPL) in the UK, NIST and PTB are presented, technical advantages of laser-based spectral radiometric calibration are analyzed, and applications of this technology are further discussed. Laser-based spectral radiometric calibration facilities can be widely used in important system-level radiometric calibration measurements with high accuracy, including radiance temperature, radiance and irradiance calibrations for space remote sensing instruments, and promote the development of aerospace, atmospheric physics, spectroscopy, biological science and so on in the fields of research and industry.
|
Received: 2013-09-22
Accepted: 2013-12-12
|
|
Corresponding Authors:
LI Zhi-gang
E-mail: lizhg@ciomp.ac.cn
|
|
[1] Anderson V E, Fox N P, Nettleton D H. Appl. Opt., 1992, 31(4), 536. [2] Brown S W, Eppeldauer G P, Lykke K R. Appl. Opt., 2006, 45(32): 8218. [3] Schuster M, Nevas S, Sperling A, et al. Appl. Opt., 2012, 51(12): 1950. [4] ZHAI Wen-chao, LI Jian-jun, ZHENG Xiao-bing, et al(翟文超,李健军,郑小兵, 等). Acta Optica Sinica(光学学报), 2012, 32(4). [5] Noorma N, Toivanen P, Manoocheri F, et al. Metrologia, 2003, 40: S220. [6] Blattner P. Achtung: Laserstrahlung. MET info, 2009, 16: 7. [7] Schaefer A R, Eckerle K L. Appl. Opt., 1984, 23: 25. [8] Zeng J, Yoon H W, Eppeldauer G P, et al. Proc. SPIE, 2009 7453, 74530N (2009). [9] Mielenz K D, Saunders R D, Shumaker J B. J. Res. Natl. Inst. Stand. Technol., 1990, 95: 49. [10] Fox N P, Martin J E, Nettleton D H. Metrologia, 1991, 28: 357. [11] Heath D F, Ahmad Z. Proc. SPIE, 2002, 4482: 94. [12] Haring R, Pollock R, Sutin B, et al. Proc. SPIE, 2005, 5883: 58830C. [13] Hoogen R, Rozanov V V, Bramstedt K, et al. Proc. SPIE, 1998, 3495: 367. [14] Noel S, Bovensmann H, Burrows J P, et al. Proc. SPIE, 1998, 3498: 94. [15] R. Dirksen R, M. Dobber M, R. Voors R, et al. Appl. Opt., 2006, 45(17): 3972. [16] Floyda L E, Herringa L C, Prinz D K, et al. Proc. SPIE, 1998, 3427: 445. [17] Rottman G, Woods T. Proc. SPIE, 1995, 2583: 347. [18] Harder J, Lawrence G, Rottman G, et al. Proc. SPIE, 2004, 4135: 204. [19] WANG Shu-rong, LI Fu-tian, SONG Ke-fei, et al(王淑荣,李福田,宋克非,等). Acta Optica Sinica(光学学报),2009,29(9): 2590. [20] WANG Yong-mei, WANG Ying-jian, WANG Wei-he, et al(王咏梅, 王英鉴, 王维和,等). Chinese Science Bulletin(科学通报), 2009, 54(23): 3778. [21] WANG Shu-rong, SONG Ke-fei, LI Fu-tian(王淑荣,宋克非,李福田). Acta Optica Sinica(光学学报), 2007,27(12): 2256. [22] Barnes R A, Brown S W, Lykke K R, et al. Proc. SPIE, 2010, 7862: 78620C. [23] Fraser G T, Brown S W, Datla R U, et al. Proc. SPIE, 2008, 7081: 708102. [24] Brown S W, Johnson B C, Feinholz M E, et al. Metrologia, 2003, 40: S81. [25] Zong Y, Brown S W, Johnson B C, et al. Appl. Opt., 2006, 45(6): 1111. |
[1] |
CUI Zhen-zhen1, 2, MA Chao1, ZHANG Hao2*, ZHANG Hong-wei3, LIANG Hu-jun3, QIU Wen2. Absolute Radiometric Calibration of Aerial Multispectral Camera Based on Multi-Scale Tarps[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(11): 3571-3581. |
[2] |
ZHANG Li-fang1, YANG Yan-xia1, ZHAO Guan-jia1, MA Su-xia1, GUO Xue-mao2. Comparison of Numerical Iterative Algorithms for Two-Dimensional Absorption Spectral Reconstruction[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(05): 1367-1375. |
[3] |
LIU Li-xi, CHEN Lin, CHEN Zhi-li*, TANG Jin, PENG Wu-di, HU Tian-you, WANG Hao-wen. Research on the Radiation Characteristics of Low-Carbon Chemical Flame Infrared Spectrum[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(01): 62-67. |
[4] |
PAN Sun-qiang, HU Peng-bing, CHEN Zhe-min, ZHANG Jian-feng, LIU Su-mei. Measurement of Vapor Hydrogen Peroxide Based on Mid Infrared Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(04): 1102-1106. |
[5] |
LIU Jia-qing1, 2, LI Zhi-zeng1, 4, LI Jing3*, LIU Lei1, 4, LIU Lei1, GUO Hong-long1, WANG Jian-guo1. Phase Characterizing and Processing in Fourier Transform Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(11): 3328-3335. |
[6] |
ZHANG Xiao-hui1, LI Xue-ping2, GAO Cheng1, 2, WANG Zhi-feng1, 2, XU Yang2, LI Chang-jun1, 2*. Spectral Characterization for Liquid Crystal Display (LCD)[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(08): 2392-2396. |
[7] |
LI Ling, WU Zhi-feng, WANG Yan-fei, DAI Cai-hong. The Effects of Light Source Differences on Array Spectroradiometer Measurements and the Research of Ultraviolet Stray Light Correction[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(03): 837-841. |
[8] |
CHEN Jia-jin1, 2, WANG Gui-shi1*, LIU Kun1, TAN Tu1, CHENG Gang1, TIAN Xing1, GAO Xiao-ming1, 2*. High Sensitivity Detection of Carbon Dioxide Based on Portable Cylindrical Multi-Pass Cell[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(01): 292-296. |
[9] |
LIU Li-ying1, ZHENG Feng2*, ZHANG Guo-yu1, XU Yi-gang2, YANG Li-yan2, Lü Wen-hua3, BIAN Ze-qiang3, CHONG Wei3, LI Ye1*. Meteorological Radiation Observation Based on Precision Solar Spectroradiometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(12): 3663-3672. |
[10] |
FANG Chen-yan1, 2, 3, LI Qing-ling1, 2, 3, YU Jin-tao1, 2, 3, YIN Da-yi1, 2, 3*. The Measurement Study and Analysis of Ultraviolet Features of High Voltage Arc and Coronaindoors[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(04): 1178-1183. |
[11] |
WANG Jian-wei, PEI Lin-lin, TAN Zheng, HUANG Min*, Lü Qun-bo, LIU Yang-yang, LI Wei-yan. Study on the Relative Radiance Calibration Method of Large Array Filter-Type Multispectral Imaging System[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(08): 2615-2618. |
[12] |
LIU Yong-sheng, HE Jian-jun*, ZHU Gao-feng, YANG Chun-hua, GUI Wei-hua. A New Method for Second Harmonic Baseline Correction and Noise Elimination on Residual Oxygen Detection in Packaged Xilin Bottle[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(08): 2598-2602. |
[13] |
HE Qi-xin1, LIU Hui-fang1, LI Bin1, PAN Jiao-qing2, WANG Li-jun2, ZHENG Chuan-tao1*, WANG Yi-ding1* . Online Detection System on Acetylene with Tunable Diode Laser Absorption Spectroscopy Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(11): 3501-3505. |
[14] |
CHEN Lin1, 2, XU Na1, 2, HU Xiu-qing1, 2*, LU Feng1, 2, ZHANG Peng1, 2 . Study on Orbit Radiometric Calibration for FY-2 Visible Band based on Deep Convective Cloud [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(08): 2639-2645. |
[15] |
XIA Hui-hui, LIU Jian-guo, XU Zhen-yu, KAN Rui-feng, HE Ya-bai, ZHANG Guang-le, CHEN Jiu-ying . Reconstruction Research for Gas Concentration and Temperature of Flame Based on Algebraic Reconstruction Technique[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(10): 2697-2702. |
|
|
|
|