Review of Normal Spectral Emissivity Standard Reference Materials |
YU Kun1, 2, 3, LIU Yu-fang1, 3*, ZHAO Yue-jin3 |
1. College of Physics & Information Engineering, Henan Normal University, Xinxiang 453007, China 2. Department of Physics, Xingyi Normal University for Nationalities, Xingyi 562400, China 3. School of Optoelectronics, Beijing Institute of Technology, Beijing 100081, China |
|
|
Abstract In order to improve the accuracy of spectral emissivity measurement, standard reference materials of spectral emissivity as the dissemination of quantity in spectral emissivity measurement are used for the calibration of spectral emissivity measurement apparatus. In the present paper, firstly the standard reference materials data proposed by the American National Institute of Standards and Technology are introduced, and some underlying standard reference materials suggested by some metering departments in Europe are analyzed in detail. For the standard reference material Armco iron and SiC proposed by some researchers, the advantages and disadvantages were explored. Finally, the characteristics of standard reference materials are summarized, and the future development of spectral emissivity measurement standard is prospected.
|
Received: 2012-04-27
Accepted: 2012-07-04
|
|
Corresponding Authors:
LIU Yu-fang
E-mail: yf-liu@henannu.edu.cn
|
|
[1] DAI Jing-min, SONG Yang, WANG Zong-wei(戴景民,宋 扬,王宗伟). Infrared and Laser Engineering(红外与激光工程), 2009, 38(4): 710. [2] Harrison W N, Joseph H M, Plyler E K, et al. National Baureau of Standards,1963, WADC-TR-59-510, Part Ⅳ. [3] Bauer W, Moldenhauer A, Oertel H. Proc of SPIE, 2006, 6205: 62050E. [4] Del Campo L, Pérez-Sáaez R B, Tello M J. Corrosion Science, 2008, 50(1): 194. [5] Wen Changda, Mudawar I. Int. J. Heat. Mass Transfer, 2006, 49(23-24): 4279. [6] Redgrove J S. High Temperatures-High Pressures, 1985, 17(2): 145. [7] Redgrove J S. Meaurement, 1990, 8(2): 90. [8] Battuello M, Lanza F, Ricolfi T. 1989, 21(3): 303. [9] Redgrove J S, Battuello M. High Temperatures-High Pressures, 1995/1996, 27/28(2): 135. [10] Deemyad S, Silvera I F. Review of Scientific Instruments, 2008, 79(8): 086105. [11] Markham J R, Solomon P R, Best P E. Review of Scientific Instruments, 1990, 61(12): 3700. [12] Zhang B, Redgrove J, Clark J. High Temperatures-High Pressures, 2003/2004, 35/36(3): 289. [13] Bauer W, Rink M, Grfen W. Tempmeko, 2004, 2: 1307. [14] Del Campo L, Pérez-Sáaez R B, Esquisabel X, et al. Review of Scientific Instruments, 2006, 77(11): 113111. [15] Del Campo L, Pérez-Sáaez R B, Tello M J, et al. International of Thermophysics, 2006, 27(4): 1160. [16] Silverman S. Journal of the Optical Society of America, 1948, 38(11): 989. [17] Morris J C. Journal of the Optical Society of America, 1961, 51(7): 798. [18] Mitchell C A. Journal of the Optical Society of America, 1962, 52(3): 341. [19] Neuer G. International of Thermophysics, 1995, 16(1): 257. [20] Neuer G, Kochendrfer R, Gern F. High Temperatures-High Pressures, 1995. 27(2): 183. [21] Neuer G, Jaroma-Weiland G. International of Thermophysics, 1998, 19(3): 917. [22] Cagran C P, Hanssen L M, Noorma M, et al. International of Thermophysics, 2007, 28(2): 581. [23] Tsai B K, DeWitt D P, Early E A, et al. Tempmeko, 2004, 2: 1179. [24] WANG Zong-wei, DAI Jing-min, HE Xiao-wa, et al(王宗伟, 戴景民, 何小瓦,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2012, 32(2): 313.
|
[1] |
ZHANG Xuan1, ZENG Chao-bin1, LIU Xian-ya1, CHEN Ping1, 2, 3*, HAN Yan2, 3. Multi-Spectral Temperature Measurement Method Based on Multivariate Extreme Value Optimization[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(03): 705-711. |
[2] |
SUN Hong-sheng1, 2, LIANG Xin-gang1, MA Wei-gang1, ZHANG Yu-feng3, QIU Chao2, MA Yue-gang2. Method and Device for Measuring High-Temperature Spectral Emissivity of Non-Conductive Materials Based on Laser Rotation Heating[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(01): 310-315. |
[3] |
XU Yan-fen1, ZHANG Kai-hua1*, LIU Yan-lei1, YU Kun1, LIU Yu-fang1, 2*. Experimental Investigation of Spectral Emissivity of Copper-Nickel Alloy During Thermal Oxidation Process[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(09): 2969-2974. |
[4] |
YU Kun1, SHI Rui-tao1, ZHANG Hui-yan1, WANG Wen-bao2, LIU Yu-fang1. Experimental Investigation of Infrared Spectral Emissivity of Pure Tungsten[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(01): 107-112. |
[5] |
ZHU Ze-zhong1,2, SHEN Hua1,2*, WANG Nian1,2, ZHU Ri-hong1,2. Transient Measure Technique for Excitation Temperature and Radiation Temperature Based on Multi-Spectral Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(02): 333-339. |
[6] |
XU Kai-pin1, YU Kun1*, ZHANG Kai-hua1, LIU Yu-fang1, 2*. The Experimental Investigation into the Emissivity of Armco A3, Steel 304 and Steel 201[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(11): 3594-3599. |
[7] |
ZHANG Fu-cai1, 2, SUN Xiao-gang1*, SUN Bo-jun1, YU Chen-tao1. Theoretical Study of Multi-Spectral Radiation Temperature Measurement Based on Temperature Difference Model[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(09): 2657-2661. |
[8] |
GU Wei-hong, MA Zhao, XING Jian*, LI Ming, SONG Wen-long. Multi Spectral True Temperature Inversion Algorithm Based on Emissivity Deviation Constraints[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(08): 2500-2504. |
[9] |
ZHU Ze-zhong1,2, SHEN Hua1,2*, WANG Nian1,2, ZHU Ri-hong1,2 . Radiation Temperature Measurement Technology Based on the Basis of Spectral Emissivity Function [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(03): 685-691. |
[10] |
ZHANG Kai-hua1, YU Kun1, ZHANG Feng2, LIU Yu-fang1, 2* . Experimental Investigation of Infrared Spectral Emissivity of Copper at 300~1 123 K [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(08): 2159-2163. |
[11] |
YU Kun1, WANG Wen-bao2, ZHANG Kai-hua1, LIU Yu-fang1* . Effects of Temperature and Heating Time on Armco Iron Spectral Emissivity in Atmospheric Environment[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(09): 2529-2532. |
[12] |
ZHANG Yu-feng, DAI Jing-min, ZHANG Yu, PAN Wei-dong, ZHANG Lei . Correction Method for Infrared Spectral Emissivity Measurement System Based on Integrating Sphere Reflectometer [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(08): 2267-2271. |
[13] |
XIN Cheng-yun, CHENG Xiao-fang*, ZHANG Zhong-zheng . Multi-Spectral Thermometry Based on Radiation Measurement within a Finite Solid-Angle [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(02): 316-319. |
[14] |
YU Kun1,2,3,LIU Yu-fang1,2*,JIA Guang-rui1,SHI De-heng2 . A Primary Study of 8~14 μm Band Emittance [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(02): 289-292. |
[15] |
WANG Zong-wei1, DAI Jing-min1, HE Xiao-wa2, YANG Chun-ling1 . The Linearity Analysis of Ultrahigh Temperature FTIR Spectral Emissivity Measurement System[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(02): 313-316. |
|
|
|
|