Quantitative Analysis of Pb,Cd,Cr and Cu in Soil Using Standard Addition Method Combined with Laser-Induced Breakdown Spectroscopy
FANG Li1,3, ZHAO Nan-jing1,3*, MA Ming-jun1,2,3, MENG De-shuo1,3, GU Yan-hong1,2,3, JIA Yao1,2,3, LIU Wen-qing1,3, LIU Jian-guo1,3
1. Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China
2. University of Science and Technology of China, Hefei 230026, China
3. Key Laboratory of Optical Monitoring Technology for Environment, Anhui Province, Hefei 230031, China
Abstract:Quantitative analysis of four heavy metals Pb, Cr, Cu and Cd in soils and solid wastes using independently developed portable system of laser-induced breakdown spectroscopy. A Nd: YAG pulse laser with fundamental wavelength of 1 064 nm is used as the excitation source, with the single pulse energy of 100 mJ the pulse width of 6 ns, and the operating frequency 3 Hz. The echelle spectroscopy with high resolution and wide spectral range is used as the spectral separation device, and the intensified charge coupled device (ICCD) as the spectral detection device in the experiment, with the detection range of 200~500 nm and a resolution of 0.08~0.12 nm. In order to improve the spectral intensity and detection sensitivity, a device of hemisphere spatially bound is used to restrain the plasma and a optical fiber with multi-channel is used collect the signal. The reception angle is 45°. The laser repetition rate is 2 Hz while the delay is 1.5 μs, with the gate width of 1.05 ms. Standard addition method is used to effectively solve the quantitative analysis of samples of unknown matrix. The innovation lies in the fact that, a curve fit instead of a straight line fit is used in the standard addition method to quantitative analyze the heavy metals in soils and solid wastes, which effectively improve the measurement results. Especially for the low concentrations of soil samples, linear fitting can not be used in quantitative analysis, in contrast, the correlation coefficient of curve fitting is much higher, more closer to the national standard measurement methods, to meet soil pollution detection. The result of seven soils and solid wastes samples are as follows, line fitting relative error: Pb 1.26%~79.38%, Cr -22.44%~82.06%, Cu 15.09%~190.50%, Cd 32.76%~167.96%, and curve fitting relative error respectively Pb -4.19%~11.92%, Cr -38.31%~9.26% , Cu -7.24%~26.86%, Cd -10.52%~12.94%, the average relative error is 10.47%.
基金资助: the support of the project of the Science and Technology program of Anhui province (1501041119), the science and technology major special program of Anhui province (15CZZ04125), the National Key Research and Development Plan (2016YFD0800902-3) and National “863” program (2014AA06A513)
通讯作者:
赵南京
E-mail: njzhao@aiofm.ac.cn
作者简介: FANG Li, (1987—),research associate, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences
e-mail:
lfang@aiofm.ac.cn
引用本文:
方 丽,赵南京,马明俊,孟德硕,谷艳红,贾 尧,刘文清,刘建国. 激光诱导击穿光谱结合标准加入法定量分析土壤中铅、镉、铬和铜[J]. 光谱学与光谱分析, 2017, 37(10): 3274-3280.
FANG Li, ZHAO Nan-jing, MA Ming-jun, MENG De-shuo, GU Yan-hong, JIA Yao, LIU Wen-qing, LIU Jian-guo. Quantitative Analysis of Pb,Cd,Cr and Cu in Soil Using Standard Addition Method Combined with Laser-Induced Breakdown Spectroscopy. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(10): 3274-3280.