Non-Invasive Detection of Blood Glucose Concentration Based on Photoacoustic Spectroscopy Combined with Principle Component Regression Method
REN Zhong1,2, LIU Guo-dong1*, HUANG Zhen1, XIONG Zhi-hua1
1. Key Laboratory of Optic-electronic Communication, Jiangxi Science and Technology Normal University, Nanchang 330038, China 2. College of Mechanical and Electrical Engineering, Nanchang University, Nanchang 330031, China
Abstract:This paper presents a photoacoustic noninvasive setup of detecting blood glucose based on the tunable pulsed laser coupled with the confocal ultrasonic transducer and the forward detection model. To validate the reliability of the setup, in the experiments, the different concentrations of glucose aqueous solution are excitated by the Q-switched 532 nm pumped Nd∶YAG pulsed laser to generate the time-resolved photoacoustic signals. And the glucose aqueous solutions are scanned by the tunable pulsed laser in the infrared waveband from 1 300 to 2 300 nm with the interval of 10nm and the photoacoustic peak-to-peak values are gotten. The difference spectral method is used to get the characteristic wavelengths of glucose, and the principle component regression algorithm is used to determine three optimal wavelengths and establish the correction mathematical model between the photoacoustic peak-to-peak values and the concentrations. The experimental results demonstrate that the mechanism of the photoacoustic signal is agreement with the cylindrical model, and the predicted results of the correction and prediction samples based on the established correction model demonstrate that the root-mean-square error of correction and prediction are all less than 10 mg·dl-1, the correlation coefficient reaches 0.993 6.
[1] SUN Chang-yue,CAO Yu-zhen,YU Song-lin,et al(孙长月, 曹玉珍, 余松林,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2014, 31(10): 2775. [2] MacKenzie H A, Ashton H S, Spiers S, et al. Clinical Chemistry, 1999,45(9): 1587. [3] Shen Y, Lu Z, Spiers S, et al. Applied Optics, 2000, 39(22): 4007. [4] Zhao Z, Myllyl R. Measurement Science and Technology, 2001, 12(12): 2172. [5] Zhao Z, Myllyl R. Applied Optics, 2005, 44(36): 7845. [6] Matti Kinnunen,Risto Myllyl. Journal of Physics D: Applied Physics, 2005, 38: 2654. [7] Christison G B. MacKenzie H A, Med. Biol. Eng. Comput.,1993, 31(3): 284. [8] Kottmann J, Rey J M, Sigrist M W. Review of Scientific Instruments, 2011, 82: 084903. [9] Kottmann J, Rey J M, Luginbühl J, et al. Biomedical Optics Express, 2012, 3(4): 667. [10] Kottmann J,Grob U, Rey J M, et al. Sensors, 2013, 13(1): 535. [11] Pleitez Rafael M , Lieblein T, Bauer A, et al. Analytical Chemistry, 2013, 85(2): 1013. [12] SHEN Yao-chun, WANG Chun, MacKenzie H A,et al(沈耀春, 王 春, MacKenzie H A,等). Journal of Nanjing University·Natural Science(南京大学学报·自然科学), 2000, 36(5): 632. [13] SHI Xiao-wei, XIAO Xiao(石小巍, 肖 啸). Infrared(红外), 2009, 30(1): 20. [14] LING Ming-sheng, QIAN Zhi-yu(凌明胜, 钱志余). Journal of Biomedical Engineering Research(生物医学工程研究), 2006, 4: 217. [15] ZENG Lv-ming, LIU Guo-dong, REN Zhong, et al. Proc. SPIE, 2009, 7280: 72802F. [16] GAO Li-li, TAO Wei, ZHAO Hui(高丽丽, 陶 卫, 赵 辉). Optical Instruments(光学仪器), 2012, 34(6): 1. [17] Diebold G J,Sun T. Acustica, 1994, 80(4): 339. [18] Tam A C. Reviews of Modern Physics, 1986, 58: 381. [19] Patel C K N. Reviews of Modern Physics, 1981, 53(3): 517. [20] Nelson E T, Patel C K N. Optics Letters, 1981, 6(7): 354. [21] Lai H M, Young K. Journal of the Acoustical Society of America, 1982, 72(6): 2000. [22] Zhao Z, Nissil S, Ahola O, et al. IEEE Transactions on Instrumentation and Measurements, 1998, 47(2): 578. [23] ZHANG Xiao-feng, CAO Hui, SHANG Zhi-yuan(张小凤, 曹 辉, 尚志远). Journal of Shanxi Normal University·Natural Sciences(陕西师范大学学报·自然科学版), 1999, 27(3): 50. [24] Seppo N, Onni A, Harri K, et al. Proc. SPIE, 1998, 3199: 2. [25] Shen Y C, MacKenzie H A, Lindberg J, et al. Proc. SPIE, 1999, 3863: 167.