Study on the Effects and Compensation Effect of Recording Parameters Error on Imaging Performance of Holographic Grating in On-Line Spectral Diagnose
JIANG Yan-xiu1, 2, Bayanheshig1*, YANG Shuo1, 2, ZHAO Xu-long1, 2, WU Na1, LI Wen-hao1
1. Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China 2. University of Chinese Academy of Sciences, Beijing 100049, China
Abstract:To making the high resolution grating, a numerical calculation was used to analyze the effect of recording parameters on groove density, focal curve and imaging performance of the grating and their compensation. Based on Fermat’s principle, light path function and aberration, the effect on imaging performance of the grating was analyzed. In the case of fixed using parameters, the error of the recording angle has a greater influence on imaging performance, therefore the gain of the weight of recording angle can improve the accuracy of the recording angle values in the optimization; recording distance has little influence on imaging performance; the relative errors of recording parameters cause the change of imaging performance of the grating; the results indicate that recording parameter errors can be compensated by adjusting its corresponding parameter. The study can give theoretical guidance to the fabrication for high resolution varied-line-space plane holographic grating in on-line spectral diagnostic and reduce the alignment difficulty by analyze the main error effect the imaging performance and propose the compensation method.
Key words:Varied-line-space plane holographic grating;Resolution;Focal curve;Groove density error;Spectral width
[1] Kim K. American Institute of Physics, 1989,184: 565. [2] Duke P H. Synchrotron Radiation. Oxford: Oxford University Press, 2000. [3] MA Dun-li(马礼敦). Introduction to Synchrotron Radiation Applications(同步辐射应用概论). Shanghai: Fudan University Press(上海: 复旦大学出版社), 2001. [4] Hofmann A. The Physics of Synchrotron Radiation. Cambridge: Cambridge University Press, 2004. [5] LIU Zu-ping(刘祖平). Physics Introduction to Synchrotron Radiation (同步辐射光源物理引论). Hefei: University of Science and Technology of China Press(合肥:中国科学技术大学出版社),2009. [6] LI Chaoyang, ZHU Junfa, WANG Qiuping. Journal of Physics:Conference Series,2013, 425:162008. [7] DU Xue-wei, SHEN Yong-cai, LI Chao-yang(杜学维,沈永才,李朝阳). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2012, 32(8): 2270. [8] Franis Polack, Lagarde B, Idir M. American Institute of Physics. Synchrotron Radiation Instrumentation: Ninth International Conference, 2007.20. [9] Noda H, Namioka T, Seya M. J. Opt. Soc. Am., 1974, 64(8): 1037. [10] Robert Grange. Applied Optics,1992, 31(19): 3744. [11] Masato Koike,Takeshi Namioka. Applied Optics,1997, 36(25): 6308. [12] LOU Jun, FU Shao-jun, XU Xiang-dong, et al(楼 俊, 付绍军, 徐向东, 等). Acta Physica Sinica(物理学报), 2006, 55(12): 6406. [13] Namioka T, Seya M, Noda H. Japan Journal of Applied Physics, 1976, 15: 1181. [14] Itou M, Harada T, Kita T. Applied Optics, 1989, 28(1): 146. [15] Lou J, Liu Y, et al. Proc. SPIE, Holography,Diffractive Optics, and Applications II, 2005, 5636: 551. [16] Hettrick M C,Underwood J H, et al. Applied Optics, 1988, 27(2): 200.