Abstract:Temperature measurement is one of the important factors for ensuring product quality, reducing production cost and ensuring experiment safety in industrial manufacture and scientific experiment. Radiation thermometry is the main method for non-contact temperature measurement. The second measurement (SM) method is one of the common methods in the multispectral radiation thermometry. However, the SM method cannot be applied to on-line data processing. To solve the problems, a rapid inversion method for multispectral radiation true temperature measurement is proposed and constraint conditions of emissivity model are introduced based on the multispectral brightness temperature model. For non-blackbody, it can be drawn that emissivity is an increasing function in the interval if the brightness temperature is an increasing function or a constant function in a range and emissivity satisfies an inequality of emissivity and wavelength in that interval if the brightness temperature is a decreasing function in a range, according to the relationship of brightness temperatures at different wavelengths. The construction of emissivity assumption values is reduced from multiclass to one class and avoiding the unnecessary emissivity construction with emissivity model constraint conditions on the basis of brightness temperature information. Simulation experiments and comparisons for two different temperature points are carried out based on five measured targets with five representative variation trends of real emissivity: decreasing monotonically, increasing monotonically, first decreasing with wavelength and then increasing,first increasing and then decreasing and fluctuating with wavelength randomly. The simulation results show that compared with the SM method, for the same target under the same initial temperature and emissivity search range, the processing speed of the proposed algorithm is increased by 19.16%~43.45% with the same precision and the same calculation results.
Key words:True temperature;Emissivity model constraint;Brightness temperature;Multispectral radiation thermometry
[1] Wen C D. Int. J. Heat Mass Transfer, 2010, 53: 2035. [2] Weng K H, Wen C D. Int. J. Heat Mass Transfer, 2011, 54: 4834. [3] Pujana J, Campo L D, Pérez-Sáez R B, et al. Meas. Sci. Technol., 2007, 18: 3409. [4] Gardner J L, Jones T P, Davies M R. High Temp. High Press, 1981, 13(4): 459. [5] Hiernaut J P, Sakuma F, Ronchi C. High Temp. High Press, 1989, 21(2): 139. [6] Khan M A, Allemand C, Eagar T W. Rev. Sci. Instrum., 1991, 62(2): 403. [7] Hagqvist P, Sikstrm F, Christiansson A K. Measurement, 2013, 46(2): 871. [8] Wang H, Chen D J, Wang J L, et al. Measurement, 2013, 46: 4023. [9] SUN Xiao-gang, LI Cheng-wei, DAI Jing-min, et al(孙晓刚, 李成伟, 戴景民, 等). Acta Metrologica Sinica(计量学报), 2002, 23(4): 248. [10] Sun X G, Zhao W, Yuan G B, et al. J. Harbin Inst. Tech., 2006, 13(4): 421. [11] SUN Xiao-gang, WANG Xue-feng, DAI Jing-min, et al(孙晓刚,王雪峰,戴景民, 等). Academic Journal of Xi’an Jiaotong University(西安交通大学学报), 2001, 35(12): 1275. [12] Sun X G, Yuan G B, Dai J M, et al. Int. J. Thermophys., 2005, 26(4): 1255. [13] SUN Kun, SUN Xiao-gang, YU Xiao-yang, et al(孙 ,孙晓刚,于晓洋). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2013, 33(6): 1719. [14] Yuan G B, Fan Z G, Sun X G, et al. International Symposium on Instrumentation Science and Technology. International Society for Optics and Photonics, 2008: 713309-713309-10.