High-Sensitive Carbon Dioxide Detection Using Quartz-Enhanced Photoacoustic Spectroscopy with a 2.0 μm Distributed Feedback Laser
LIU Xiao-li1, WU Hong-peng1, SHAO Jie2, DONG Lei1*, ZHANG Lei1, MA Wei-guang1, YIN Wang-bao1, JIA Suo-tang1
1. State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan 030006, China 2. Institute of Information Optics, Zhejiang Normal University, Jinhua 321004, China
Abstract:A carbon dioxide (CO2) sensor is developed using quartz enhanced photoacoustic spectroscopy (QEPAS) with a 2.0 μm distributed feedback diode laser. The detection is based on a 2f wavelength-modulation spectroscopy approach by dithering and scanning the laser current. The laser modulation depth is optimized at normal atmosphere pressure and room temperature. The influence of the H2O presence in the sample gas mixture on the CO2 sensor performance is also investigated. The results show that, with 1% CO2 concentration, the H2O in the concentration ranges of 0 to 0.2% has an effect on the CO2 signal amplitude and phase, and the largest amplitude difference is ~2.1 times. When the H2O concentration is over 0.2%, the CO2 signal amplitude is saturated and remains steady. Atmospheric CO2 concentration is well measured using the optimal sensor parameters. Benefiting from the strong absorption line intensity at 4 989.97 cm-1, a detection limit of 19 ppm (1σ, 300 ms averaging time) is achieved, which corresponds to a normalized noise equivalent absorption coefficient of 4.71×10-9 cm-1·W·Hz-1/2.
[1] Barsan N, Hübner M, Weimar U, Sens. Actuators B, 2011, 157(2): 510. [2] CHEN Chang-lun, HE Jian-bo, LIU Wei, et al(陈长伦,何建波,刘 伟,等). Sensor World(传感器世界), 2004, 10(4): 11. [3] Zhuiykov S, Miura N, Sens. Actuators B, 2007, 121(2): 639. [4] Melendez J, de Castro A. J, Lopez F, et al. Sens. Actuators A, 1995, 46-47: 417. [5] Corman T, Kalvesten E, Huiku M, et al. J. Microelectromech S, 2000, 9(4): 509. [6] ZHENG Hua-dan, DONG Lei, LIU Yan-yan, et al(郑华丹,董 磊,刘研研,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2013, 33(12): 3187. [7] Kosterev A A, Bakhirkin Y A, Curl R F, et al. Opt. Lett., 2002, 27(21): 1902. [8] Kosterev A A, Tittel F K, Serebryakov D V, et al. Rev. Sci. Instrum.,2005, 76(4): 043105. [9] Dong L, Wright J, Peters B, et al. Appl. Phys. B, 2012, 107(2): 459. [10] Dong L, Kosterev A A, Thomazy D, et al. Proc. of SPIE, 2011, 7945. [11] Dong L, Kosterev A A, Thomazy D, et al. Appl. Phys. B, 2010, 100(3): 627. [12] Kosterev A A, Bakhirkin Y A, Tittel F K, et al. Appl. Phys. B, 2008, 92(1): 103. [13] Taylor R L, Bitterman S, Rev. Mod. Phys., 1969, 41(1): 26. [14] Wysocki G, Kosterev A A, Tittel F K, Appl. Phys. B, 2006, 85(2) : 301-306. [15] Veres A, Bozoki Z, Mohacsi A, et al. Appl. Spectrosc., 2003, 57(8): 900.