Abstract:There are some challenges in near-infrared non-invasive blood glucose measurement, such as the low signal to noise ratio of instrument, the unstable measurement conditions, the unpredictable and irregular changes of the measured object, and etc. Therefore, it is difficult to extract the information of blood glucose concentrations from the complicated signals accurately. Reference measurement method is usually considered to be used to eliminate the effect of background changes. But there is no reference substance which changes synchronously with the anylate. After many years of research, our research group has proposed the floating reference method, which is succeeded in eliminating the spectral effects induced by the instrument drifts and the measured object’s background variations. But our studies indicate that the reference-point will changes following the changing of measurement location and wavelength. Therefore, the effects of floating reference method should be verified comprehensively. In this paper, keeping things simple, the Monte Carlo simulation employing Intralipid solution with the concentrations of 5% and 10% is performed to verify the effect of floating reference method used into eliminating the consequences of the light source drift. And the light source drift is introduced through varying the incident photon number. The effectiveness of the floating reference method with corresponding reference-points at different wavelengths in eliminating the variations of the light source drift is estimated. The comparison of the prediction abilities of the calibration models with and without using this method shows that the RMSEPs of the method are decreased by about 98.57%(5%Intralipid)and 99.36%(10%Intralipid)for different Intralipid. The results indicate that the floating reference method has obvious effect in eliminating the background changes.
王柱楼,张婉洁,李晨曦,陈文亮*,徐可欣 . 应用浮动基准法修正光谱光源漂移影响的模拟验证 [J]. 光谱学与光谱分析, 2015, 35(02): 547-551.
WANG Zhu-lou, ZHANG Wan-jie, LI Chen-xi, CHEN Wen-liang*, XU Ke-xin . The Validation of the Effect of Correcting Spectral Background Changes Based on Floating Reference Method by Simulation . SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(02): 547-551.
[1] Olesberg J T, Liu L, Zee V V, et al. Analytical Chemistry, 2006, 78(1): 215. [2] Tarumi M, Shimada M, Murakami T, et al. Physics in Medicine and Biology, 2003, 48(15): 2373. [3] Amerov A K, Chen J, Arnold M A. Applied Spectroscopy, 2004, 58:1195. [4] XU Ke-xin, LIU Rong(徐可欣,刘 蓉). China Patent(中国专利):200510013373. [5] LIU Rong, XU Ke-xin, CHEN Wen-liang(刘 蓉, 徐可欣, 陈文亮). Science in China(中国科学), 2007, 37(B10): 124. [6] CHEN Wen-liang, YANG Yue, XU Ke-xin, et al(陈文亮, 杨 越, 徐可欣, 等). Nanotechnology and Precision Engineering(纳米技术与精密工程), 2007, 5(4): 298. [7] YANG Yue, CHEN Wen-liang, SHI Zhen-zhi, et al(杨 越, 陈文亮, 史振志, 等). Chinese Optics Letters, 2010, 4: 25. [8] Wang L, Jacques SL, Zheng L. Computer Methods and Programs in Biomedicine, 1995, 47(2): 131. [9] Matthias Kohl, Matthias Essenpreis,Mark Cope. Physics in Medicine and Biology, 1995, 40:1267. [10] Liu Rong, He Bin, Xu Kexin, et al. Proc. SPIE, 2009, 7186:71860O.