Abstract:In order to reduce the effect of the spectral line self-absorption on the analysis result in the laser induced plasma and enhance the qualities of spectrum, the spectral information was recorded by the spectral analysis system consisting of a modular multifunctional grating spectrometer and a CCD detector etc., and the electron temperature and electron density of the plasma were measured with the spectroscopic methods. A plane mirror device was used to constraint the laser plasma, and a reasonable explanation was got through comparing the linear evolution under different experimental conditions and measuring the temperature, electronic density and sample evaporation. The result shows that when an appropriate plane mirror device was used to constraint the laser plasma, the axial temperature of the plasma increased and the radial distribution of the plasma becomes uniform; the electron density increased dramatically; however, obviously sample evaporation decreased, which may be the reasons for being able to effectively reduce the level of self-absorption spectral lines. Therefore, the plane mirror device could reduce the self-absorption effect in the laser-induced plasma. This makes it possible to choose a sensitive line that acts as analysis line in the quantitative analysis of the major elements. In other words, this promotes the measurement precision in the laser-induced breakdown spectroscopy.
Key words:Laser-induced breakdown spectroscopy;Self-absorption effect;Plane-mirrors;Electron temperature;Electron density
陈金忠,马瑞玲,王 敬,李 旭,苏红新 . 激光诱导金属等离子体中的自吸效应研究 [J]. 光谱学与光谱分析, 2014, 34(09): 2337-2341.
CHEN Jin-zhong, MA Rui-ling, WANG Jing, LI Xu, SU Hong-xin . Study of Self-Absorption Effect on Laser-Induced Metal Plasma . SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(09): 2337-2341.
[1] CHEN Jin-zhong, SONG Guang-ju, SUN Jiang, et al(陈金忠,宋广聚,孙 江,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2012, 32(1): 37. [2] Sarkar A, Alamelu D-Aggarwal S K. Optics and Laser Technology, 2012, 1(44): 30. [3] Ermalitskaia F E, Voropay Y S, Zajogin A P. Journal of Applied Spectroscopy, 2012, 77(2): 153. [4] Gondal M A, Dastageer A, Maslehuddin M, et al. Optics and Laser Technology, 2012, 3(44): 566. [5] Haider A F, Khan Z H. Optics & Laser Technology, 2012, 6(44): 1654. [6] Elsayed K, Imam H, Harfoosh A, et al. Optics and Laser Technology, 2012, 1(44): 130. [7] Zhang J, Ma H H, Xi J H, et al. Journal of Analytical Atomic Spectrometry, 2012, 27: 1903. [8] Sabsabi M, CIelo P. Applied Spectroscopy, 1995, 49, (4): 499. [9] Aragon C, Aguilera J A, Penalba F. Applied Spectrosc., 1999, 53: 1259. [10] Sabsabi M, Cielo P. Applied Spectroscopy, 1995, 49(4): 499. [11] Sherbini A M, Aamer A A. Scientific Research, 2012, 3: 502. [12] Andrey M P, Francesco C, Roberta F. Journal of Analytical Atomic Spectromery, 2009, 24: 602. [13] Ahmed A I, Khalil A I. Optical & Laser Technology, 2013, 45: 443. [14] YU Shi-juan, CHEN Jin-zhong, SU Hong-xin, et al(玉世娟,陈金忠,苏红新,等). Metallurgical Analysis(冶金分析),2010, 30(10): 11. [15] Griem H R. Plasma Spectroscopy. New York: McGraw-Hill, 1964: 375. [16] Ashraf M E, Abdel A S. Scientific Research, 2012, 2: 278.