Wavelength Selection of the Oximetry Based on Test Analysis of Variance
LIN Ling1, LI Wei1, ZENG Rui-li2, LIU Rui-an3, LI Gang4, WU Xiao-rong3*
1. State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China 2. Department of Automobile Engineering, Military Transportation University, Tianjin 300161, China 3. College of Physics & Electronic Information, Tianjin Normal University, Tianjin 300087, China 4. Tianjin Key Laboratory of Biomedical Detecting Techniques & Instruments, Tianjin University, Tianjin 300072, China
Abstract:In order to improve the precision and reliability of the spectral measurement of blood oxygen saturation,and enhance the validity of the measurement, the method of test analysis of variance was employed. Preferred wavelength combination was selected by the analysis of the distribution of the coefficient of oximetry at different wavelength combinations and rational use of statistical theory. Calculated by different combinations of wavelengths (660 and 940 nm, 660 and 805 nm and 805 and 940 nm) through the clinical data under different oxygen saturation,the single factor test analysis of variance model of the oxygen saturation coefficient was established, the relative preferabe wavelength combination can be selected by comparative analysis of different combinations of wavelengths from the photoelectric volume pulse to provide a reliable intermediate data for further modeling. The experiment results showed that the wavelength combination of 660 and 805 nm responded more significantly to the changes in blood oxygen saturation and the introduced noise and method error were relatively smaller of this combination than other wavelength combination,which could improve the measurement accuracy of oximetry. The study applied the test variance analysis to the selection of wavelength combination in the blood oxygen result measurement,and the result was significant. The study provided a new idea for the blood oxygen measurements and other related spectroscopy quantitative analysis. The method of test analysis of variance can help extract the valid information which represents the measured values from the spectrum.
Key words:The analysis of variance;Oximetry;Wavelength selection;Photoplethysmography (PPG)
林 凌1,李 威1,曾锐利2,刘瑞安3,李 刚4,吴晓荣3* . 基于试验方差分析的血氧测量波长选取的研究 [J]. 光谱学与光谱分析, 2014, 34(07): 2005-2009.
LIN Ling1, LI Wei1, ZENG Rui-li2, LIU Rui-an3, LI Gang4, WU Xiao-rong3* . Wavelength Selection of the Oximetry Based on Test Analysis of Variance . SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(07): 2005-2009.
[1] ZHANG Fang-jun,SHAO Jun,QIAN Wei-ying,et al(张芳君,邵 军,钱蔚颖,等). Chinese Journal of Otorhinolaryngology-Skull Base Surgery(中国耳鼻咽喉颅底外科杂志),2013,19(1):Friebel M. [2] RUN Han,DONG Xiao-song,LI Yu-qian,et al(闰 涵,董霄松,李玉茜,等). National Medical Journal of China(中华医学杂志),2013,93(6):415. [3] Cannesson M,Talke P. F1000 Medicine Reports,2009. 1. [4] SUN Jian(孙 健). China Metrology(中国计量),2013,(1):112. [5] Vazquez-Jaccaud C,Paez G,Strojnik M,et al. Annals of Biomedical Engineering,2011,39(7):1994. [6] Uyuklu M,Canpolat M,Meiselman H J,et al. Journal of Biomedical Optics,2011,16(11):117006. [7] Vansickel A R, Shihadeh A, Eissenberg T. Tob Control, 2012, 21(3): 377. [8] LI Zhong-hou,SU Yong-an,LIU Xiao-ping,et al(李忠厚,苏永安,刘小平,等). Surface Technology(表面技术),1995,6:012. [9] Liu S,Rovine M J,Molenaar P C M,et al. Psychological Methods,2012,17(1):15. [10] Fantini S,Francheschini A M. Chapter 7 in Handbook of Optical Biomedical Diagnostics, V. V. Tuchin, Ed., SPIE Press, Bellingham, WA,2002. 405. [11] LI Gang,WANG Yan,LI Qiu-xia,et al(李 刚,王 焱,李秋霞,等). Journal of Infrared and Millimeter Waves,2006, 25(5): 345. [12] LIU Guang-da,GUO Wei,ZHU Ping,et al(刘光达,郭 维,朱 平,等). Laser & Infrared(激光与红外),2009,39(2):169.