Abstract:When the spectra of the diffuse reflectance of low reflectivity samples or the transmittance of low transmisivity samples are measured by a portable near infrared (NIR) spectrometer, because there is the noise of the spectrometer, the smaller the reflectance or transmittance of the sample, the lower its SNR. Even if treated by denoise methods, the spectra can not meet the requirement of NIR analysis. So the equivalent spectrum measure method was researched. Based on the intensity of the reflected or transmitted signal by the sample under the traditional measure conditions, the light current of the spectrometer was enlarged, and then the signal of the measured sample increased; the reflected or transmitted light of the measure reference was reduced to avoid the signal of the measure reference over range. Moreover the equivalent spectrum of the sample was calculated in order to make it identical with the spectrum measured by traditional method. Thus the NIR spectral SNR was improved. The results of theory analysis and experiments show that if the light signal of the spectrometer was properly increased according to the reflected or transmitted signal of the low reflectivity or transmisivity sample, the equivalent spectrum was the same as the spectrum measured by traditional method and its SNR was improved.
Key words:Portable NIR spectrometer;Equivalent spectrum;Measure method;SNR;Lightness control
王智宏,刘 杰,孙玉洋,滕 飞,林 君* . 近红外等效光谱测量方法研究 [J]. 光谱学与光谱分析, 2013, 33(04): 963-967.
WANG Zhi-hong, LIU Jie, SUN Yu-yang, TENG Fei, LIN Jun* . Research on NIR Equivalent Spectral Measurement . SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(04): 963-967.
[1] LU Wan-zhen(陆婉珍). Modern Analysis Technique of Near-Infrared Spectrum, 2nd ed.(现代近红外光谱分析技术,第2版). Beijing:China Petrochemical Press, 2006. 30. [2] Blanco M,Villarroya I. Trends in Analytical Chemistry,2002, 21(4): 240. [3] Luis Fermín Capitán-Vallveya, Alberto J Palmab. Analytica Chimica Acta, 2011, 699(1-2): 27. [4] YE Hua-jun, XIA A-lin, ZHANG Xue-feng, et al(叶华俊,夏阿林,张学锋,等). Chinese Journal of Scientific Instrument(仪器仪表学报),2012, 33(1): 85. [5] Masanori Kumagai, Naganori Qhisa, Toshio Amano, et al. Analytical Sciences, 2003, 19(11): 1553. [6] Alper Bozkurt, Arye Rosen, Harel Rosen, et al. BioMedical Engineering OnLine, 2005, 4(1): 29. [7] Tharshan Vaithianathan, Iain D C Tullis, Nicholas Everdell, et al. Review of Scientific Instruments, 2004, 75(10): 3276. [8] Jeffrey A Cramer, Robert E Morris, Mark H Hammond, et al. Energy and Fuels,2009, 23(2), 1132. [9] Edvaldo da Nóbrega Gaiao, Sérgio Ricardo Bezerra dos Santos, Vagner Bezerra dos Santos, et al. Talanta,2008, 75(3), 792. [10] Viscarra Rossel R A, Cattle S R, Ortega A, et al. Geoderma.,2009, 150(3-4):253. [11] QIAN Yu-lin, ZHANG Yang(钱玉麟, 张 洋). Industrial Minerals & Processing(化工矿物与加工), 2011, 40(1):25. [12] YAN Yan-lu(严衍禄). The Theory and Application of Near Infrared Spectrum Analysis(近红外光谱分析基础与应用). Beijing: China Light Industry Press(北京: 中国轻工业出版社), 2005. 98. [13] WANG Zhi-hong, LIN Jun, WU Zi-yu, et al(王智宏, 林 君,武子玉,等). Chinese Journal of Scientific Instrument(仪器仪表学报),2005, 26(11): 1135. [14] WANG Zhi-hong, LIU Jie, YU Yong, et al(王智宏,刘 杰,于 永,等). Chinese Patent(中国专利), 201210291003. 6,2012. 8.