Abstract:In the present article, the ordinary printing paper was immerged in the aqueous solution of CuCl2, and used as an absorber for the enrichment of heavy metal copper in liquid, After being taken from the solution and dried, the paper was then analyzed using laser-induced breakdown spectroscopy. This method overcomes the drawbacks of splashing and low sensitivity in the process of direct analysis of heavy metal in water sample with LIBS. The Cu 324.7 nm spectral line was used as the analysis line in experiment. The variation in the line intensity at different enrichment time was studied. The calibration curve for the quantitative measurement of Cu in water was established, the detection limit was 0.023 mg·L-1, which is about three orders of magnitude improvement compared with that in ordinary LIBS analysis of heavy metal in solution. It is likely that this technique will be practically helpful in the sensitive analysis of the heavy metal in water.
钱惠国,周卫东* . 水溶液中微量Cu元素的激光诱导光谱检测[J]. 光谱学与光谱分析, 2012, 32(10): 2820-2823.
QIAN Hui-guo, ZHOU Wei-dong*. Determination of Trace Cu in Water by Laser-Induced Breakdown Spectroscopy. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(10): 2820-2823.
[1] Dhara S, Misra N L, Aggarwal S K. Spectrochimica Acta Part B: Atomic Spectroscopy, 2008, 63(12): 1395. [2] Pei L, Qin Y C, Hu B, et al. Analytica Chimica Acta, 2001, 440(2): 207. [3] Ndung’u K, Ranville M A, Franks R P, et al. Marine Chemistry, 2006, 98(2): 109. [4] Lemos V A, Franca R S, Moreira B O. Separation and Purification Technology, 2007, 54(3): 349. [5] Wang C, Wu Q H, Wu C X, et al. Journal of Hazardous Materials, 2011, 185(1): 71. [6] Hanif M, Salik M, Baig M. Optics and Lasers in Engineering, 2011, 49(12): 1456. [7] Zhou W D, Li K X, Li X F, et al. Opt. Lett., 2011, 36(15): 2961. [8] Li K X, Zhou W D, Shen Q M, et al. Spectrochimica Acta Part B, 2010, 65(5): 420. [9] Cheri M S, Tavassoli S H. Applied Optics, 2011, 50(9): 1227. [10] Hussain T, Gondal M A. Bull Environ Contain Toxicol, 2008, 80: 561. [11] Fang X, Ahmad S R. Applied Spectroscopy, 2007, 61(9): 1021. [12] Alamelu D, Sarkar A, Aggarwal S K. Talanta, 2008, 77(1): 256. [13] Chen Z J, Li H K, Liu M, et al. Spectrochimica Acta Part B: Atomic Spectroscopy, 2008, 63(1): 64. [14] Nirnam E S, Scorr R G. Applied Spectroscopy, 2002, 56(3): 370. [15] SHI Huan, ZHAO Nai-jing, WANG Chun-long, et al(石 焕, 赵南京, 王春龙,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2012, 32(1): 25. [16] Cheri M S, Tavassoli S H. Applied Optics, 2011, 50(9): 1227. [17] Pavel Y, Richard J S M, Doug B, et al. Spectrochimica Acta Part B, 2005,60(7-8): 986.