Influence of Lighting Sources Spectra on the Human Visual Brightness Identification under the Mesopic Vision
YANG Yong1,2, GUAN Li3, ZHU Chuan-zheng1,2, ZHU Li-wei1,2, XU Nuo1,2, LI Xu3, LI Pan-lai3
1. Research Institute of Highway, Ministry of Transport, Beijing 100088, China 2. Key Laboratory of Road Safety, Ministry of Communications PRC, Beijing 100088, China 3. College of Physics Science and Technology, Hebei University, Baoding 071002, China
Abstract:Based on the MOVE models and the measurement of emission spectra of various light sources, the photopic function weights x and the mesopic equivalent brightness of human visual spectral luminous efficiency in different background brightness were calculated. Results showed that in the mesopic scope, human visual function peak value gradually increases with the brightness decreasing, and is moving towards the short-wave direction. The change rate is inversely proportional to the s/p index. In the case of ambient brightness for 0.5 cd·m-2, peak values increase by 30% compared to the photopic function. Compared to the traditional test results, the mesopic equivalent brightness of fluorescent lamp and other different color temperature white light LED showed a positive gain that reaches 40%. On the other hand, the high pressure sodium lamp showed a negative gain. Results also showed that there was a decreasing trend when the ambient light level increased, and once the brightness level reaches that when cone cells play a full role, the equivalent brightness will equal photopic brightness. The methods and conclusions of this paper can help evaluate light sources, light-emitting material spectrum and characteristics of apparent brightness.
杨 勇1,2,关 丽3,朱传征1,2,朱立伟1,2,许 诺1,2,李 旭3,李盼来3 . 中间视觉条件下光源光谱对人眼视亮度的影响[J]. 光谱学与光谱分析, 2012, 32(10): 2628-2631.
YANG Yong1,2, GUAN Li3, ZHU Chuan-zheng1,2, ZHU Li-wei1,2, XU Nuo1,2, LI Xu3, LI Pan-lai3 . Influence of Lighting Sources Spectra on the Human Visual Brightness Identification under the Mesopic Vision. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(10): 2628-2631.
[1] Cao D C, Pokorny J, Grassi M A. Documenta Ophthalmol., 2011, 123: 29. [2] Gabriel Katz, Hani Levkovitch-Verbin, Giora Treister. Graefe’s Archive for Clinical and Experimental Ophthalmology,2010, 248: 1699. [3] Palmer D A. Nature, 1966, 209: 276. [4] Ikeda M S H. Journal of the Optical Society of America., 1981, 3(1): 71. [5] Sagawa K, Takeichi K. Journal of the Optical Society of America A: Optics and Image Science, 1986, 3(1): 71. [6] He Y, Rea M S, Bierman A B J. J. Illum. Eng. Soc., 1997, (26): 125. [7] Rea M S, Bullough J D, Freyssinier J P. Lighting Res. Technol., 2004, 36: 85. [8] Freiding A, Eloholma M, Ketonmaki J. Lighting Res. Technol.,2007, 39: 319. [9] Walkey H, Orrevetelainen P, Barbur J. Lighting Res. Technol.,2007, 39: 335. [10] Varady G, Freiding A, Eloholma M. Lighting Res. Technol.,2007, 39: 355. [11] Goodman T, Forbes A, Wallkey H. Lighting Res. Technol.,2007, 39: 365. [12] ZHAO Jian-dong, YANG Yong, LI Zhao-xuan(赵建东,杨 勇,李兆轩). Opt. Precision Eng.(光学精密工程), 2012, 20(2): 220. [13] JIN Peng, YU Chun-yu, ZHOU Qi-feng, et al(金 鹏,喻春雨,周奇峰,等). Opt. Precision Eng.(光学精密工程), 2011, 19(1): 51. [14] Jin P, Wang Y F, Zhou Q F. Optoelectronics Letters,2009, 5(4): 265.