Abstract:The present paper introduced a spectral calibration method to calibrate a large aperture infrared radiation facility. We developed a radiometer which consisted of optical system, infrared detectors(cavity pyroelectric detector and HgCdTe detector 2~14 μm), fine mechanical modulator, lock in amplifier, signal processor, etc. At first, we analyzed the method on how to measure the spectral calibration of the large aperture infrared radiometer, and established the spectral calibration facility. Then, we tested the nonlinear response for the cavity pyroelectric detector and HgCdTe detector. Finally, we used the cavity pyroelectric detector to calibrate the relative spectral responsivity of HgCdTe detector at several wavelengths on the facility. Through the comparison of the two methods for measuring the relative spectral responsivity, the average of multiple measurements and comparative analysis of two methods were given. The uncertainty analysis of the whole system showed that the measurement uncertainty of the facility was better than 3.4%.
叶 钊1, 2,万 志1,李宪圣1,任建伟1*,刘洪兴1, 2 . 大口径红外辐射计的光谱定标[J]. 光谱学与光谱分析, 2012, 32(07): 1994-1998.
YE Zhao1, 2, WAN Zhi1, LI Xian-sheng1, REN Jian-wei1*, LIU Hong-xing1, 2 . Spectral Calibration for the Large Aperture Infrared Radiometer . SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(07): 1994-1998.
[1] HU Xiu-qing, ZHANG Li-yang, ZHENG Zhao-jun, et al(胡秀清,张里阳,郑照军,等). Optics and Precision Engineering(光学精密工程), 2010, 18(9): 1972. [2] SUN Xue-jin, LIU Jian, MAO Jie-tai(孙学金, 刘 剑, 毛节泰). J. Infrared Millim. Waves(红外与毫米波学报), 2009, 28(1): 54. [3] REN Jian-wei, WAN Zhi, LI Xian-sheng, et al(任建伟, 万 志,李宪圣,等). Optics and Precision Engineering(光学精密工程), 2007, 15(8):1186. [4] Theocharous E, Engtrakul C, Dillon A C, et al. Applied Optics, 2008, 47(22): 3999. [5] James G A, Philip A, Gail B, et al. Transactions American Geophysical Union, 2007, 88(11): 136. [6] ZHENG Yu-quan(郑玉权). Optics and Precision Engineering(光学精密工程), 2010, 18(11): 2347. [7] Theocharous E. Metrologia, 2006, 43: 115. [8] Theocharous E, Ishii J, Fox N P. Applied Optics, 2004, 43(21): 4182. [9] Theocharous E, Ishii J, Fox N P. Infrared Physics And Technology, 2005, 46(4): 309. [10] REN Jian-wei, LIU Ze-xun, WAN Zhi, et al(任建伟, 刘则洵, 万 志,等). Optics and Precision Engineering(光学精密工程), 2010, 18(7): 1491.