Abstract:The Kennard/Stone(K/S) algorithm is adopted to select the transfer set samples in the near infrared analysis calibration transfer by calculating the Euclidean distance of the spectrum of the samples. In order to get a best expression of the comparability of the samples and select the best samples for calibration transfer, piecewise direct standardization (PDS) algorithm was investigated for resolving calibration transfer of near-infrared spectra of mixed amine, then the Euclidean distance and the Mahalanobis distance were applied to calculate the comparability of the spectra of the samples and the standard error of prediction (SEP) was used to evaluate them. The combination of spectral difference and property difference was introduced to estimate the effect of individual spectral difference and property difference. The experimental results showed that the Mahalanobis distance was better than the Euclidean distance in PDS and the combination of spectral difference and property difference was more effective in expressing the comparability of the samples.
Key words:Calibration transfer;Piecewise direct standardization;Kennard/Stone algrithm;Mahalanobis distance
李 华,王菊香*,邢志娜,申 刚. 改进的K/S算法对近红外光谱模型传递影响的研究 [J]. 光谱学与光谱分析, 2011, 31(02): 362-365.
LI Hua,WANG Ju-xiang*,XING Zhi-na,SHEN Gang . Influence of Improved Kennard/Stone Algorithm on the Calibration Transfer in Near-Infrared Spectroscopy . SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(02): 362-365.
[1] LU Wan-zhen(陆婉珍). Medern Analysis Technique of NIR(现代近红外光谱分析技术). Beijing: China Petrochemical Press(北京:中国石化出版社),2006. 1. [2] Wang Y D, Kowalski B R. Appl. Spectrosc., 1992, 46:764. [3] Walczak B, Bouveresse E, Massart D L. Chemometrics Intelligent Laboratory Systems, 1997, 36: 41. [4] Wold S, Antti H, Lindgren F. Chemometrics Intelligent Laboratory Systems, 1998, 44: 175. [5] Bergman Eva-Latta, Brage Henric, Josefson Mats. Journal of Pharmaceutical and Biomedical Analysis, 2006, 41: 86. [6] Alamar M Carmen, Bobelyn Els, Lammertyn Jeroen. Postharvest Biology and Technology, 2007, 45: 38. [7] QIN Chong, CHEN Wen-wen, HE Xiong-kui, et al(秦 冲,陈雯雯,何雄奎, 等). Spectoscopy and Spectral Analysis(光谱学与光谱分析), 2009,29(10):2661. [8] Kennard R W, Stone L A. Technometrics, 1969, 11: 137. [9] Bouveresse E, Massart D L. Chemometrics Intelligent Laboratory Systems, 1996, 32: 201. [10] Jeongah Yoon, Byungwoo Lee, Chonghun Han. Chemometrics and Intelligent Laboratory Systems, 2002, 64: 1. [11] Wang Y, Veltkamp D J, Kowalski B R. Analytical Chemistry, 1991, 63: 2570. [12] Cen Haiyan, Bao Yidan, He Yong. Journal of Food Engineering, 2007, 82: 253. [13] Brown David J, Shepherd Keith D, Walsh Markus G. Geoderma., 2006, 132: 273. [14] Liu Yande, Ying Yibin. Postharvest Biology and Technology, 2005, 37: 65.