Concentration Retrieving Method of SO2 Using Differential Optical Absorption Spectroscopy Based on Statistics
LIU Bin1, SUN Chang-ku1*, ZHANG Chi1, ZHAO Yu-mei2, LIU Jun-ping2
1. State Key Lab of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China 2. Tianjin Lanyu Technology Co. Ltd, Tianjin 300384, China
Abstract:A concentration retrieving method using statistics is presented, which is applied in differential optical absorption spectroscopy (DOAS) for measuring the concentration of SO2. The method uses the standard deviation of the differential absorption to represents the gas concentration. Principle component analysis (PCA) method is used to process the differential absorption spectrum. In the method, the basis data for the concentration retrieval of SO2 is the combination of the PCA processing result, the correlation coefficient, and the standard deviation of the differential absorption. The method is applied to a continuous emission monitoring system (CEMS) with optical path length of 0.3 m. Its measuring range for SO2 concentration is 0~5 800 mg·m-3. The nonlinear calibration and the temperature compensation for the system were executed. The full scale error of the retrieving concentration is less than 0.7%FS. And the measuring result is -4.54 mg·m-3 when the concentration of SO2 is zero.
Key words:DOAS;Concentration retrieving;Statistics;PCA;Flue gas monitoring