1. Institute of Laser Life Science, South China Normal University, Guangzhou 510631, China 2. First Affiliated Hospital of Sun Yat-sen University of Medical Sciences, Guangzhou 510089, China
Abstract:A double-integrating-spheres system, the basic principle of measuring technology of radiation, and an optical model of biological tissues were used for the study. Optical properties of human normal bladder tissue at 476.5, 488, 496.5, 514.5 and 532 nm of laser and their linearly polarized laser irradiation were studied. The results of measurement showed that total attenuation coefficient and scattering coefficient of human normal bladder tissue at these wavelengths of laser and their linearly polarized laser irradiation increased with decreasing wavelengths. And these was an obvious distinction between the results at these wavelengths of laser and their linearly polarized laser irradiation. Absorption coefficient of human normal bladder tissue at these wavelengths of laser and their linearly polarized laser irradiation was tardily increased with decreasing wavelengths. But there were a number of gurgitations. And these were independent of the wavelengths of laser or their linearly polarized laser irradiation. Mean cosine of scattering of human normal bladder tissue at these wavelengths of laser and their linearly polarized laser irradiation also increased with decreasing wavelengths. And these was an obvious distinction with these wavelengths of laser and their linearly polarized laser irradiation. But penetration depth of human normal bladder tissue at these wavelengths of laser and their linearly polarized laser irradiation also increased with increasing wavelengths. But there were a number of gurgitations. Refractive index of human normal bladder tissue at these wavelengths of laser ranged from 1.37 to 1.44. Absorption coefficient, scattering coefficient, total attenuation coefficient, and effective attenuation coefficients of human normal bladder tissue in Kubelka-Munk two-flux model at the same wavelength of laser and the linearly polarized laser irradiation do not exhibit prominent distinction (P>0.05). Some absorption coefficient, scattering coefficient, total attenuation coefficient, and effective attenuation coefficient of human normal bladder tissue in Kubelka-Munk two-flux model at different wavelengths of laser and their linearly polarized laser irradiation exhibit obvious distinction.
Key words:Human normal bladder;Optical properties;Ar+ laser and 532 nm laser;Double-integrating-sphere system;Linearly polarized laser
魏华江1,邢 达1*,巫国勇2,金 鹰1,谷怀民1 . 5个不同波长的激光及其线偏振激光辐照人正常膀胱组织光学特性 [J]. 光谱学与光谱分析, 2004, 24(09): 1039-1041.
WEI Hua-jiang1,XING Da1*,WU Guo-yong2,JIN Ying1,GU Huai-min1 . Optical Properties of Human Normal Bladder Tissue at Five Different Wavelengths of Laser and Their Linearly Polarized Laser Irradiation in Vitro . SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24(09): 1039-1041.
[1] Yong Kai Y, Morgan Stephen P, Stockford Ian M et al. J. Biomed. Opt., 2003, 8(3): 504. [2] Guzelsu Nejat, Federici John F, Lim Hee C et al. J. Biomed. Opt., 2003, 8(1): 80. [3] Sankaran Vanitha, Walsh Joseph T, Maitland Duncan J. J. Biomed. Opt., 2002, 7(3): 300. [4] Zimnyakov D A, Sinichkin Yu P, Kiseleva I V et al. Opt. Spectrosc., 2002, 92(5): 765. [5] Chernomordik Victor, Hattery David W, Grosenick Dirk et al. J. Biomed. Opt., 2002, 7(1): 80. [6] Chance B, Cope M, Gratton E et al. Review of Scientific Instruments, 1998, 69(10): 3457. [7] Qu Jianan,MacAulay Calum, Lam Stephen et al. Appl. Opt., 1994, 33(31): 7397. [8] WEI Hua-jiang, XING Da, WU Guo-yong et al(魏华江,邢 达,巫国勇等). Spectroscopy and Spectral Analysis(光谱学与光谱分析),已录用,待发表. [9] Bolin F P, Preuss L E et al. Proc. Appl. Opt., 1989, 28(12): 2297. [10] Li H, Lu Z. Proc. SPIE, 1998, 3548: 119. [11] Rogatkin D A. Opt. Spectrosc., 1999, 87(1): 101.