Abstract:In order to improve the radiation characteristic of laser-induced plasma, with the national standard soil taken as the target sample, a laser spectrum analytical system which composed of a high-energy neodymium glass laser, a multifunctional and compact integrated spectrometer, and a CCD detector was used to detect the influence of the NaCl sample additive on the laser plasma radiation intensity. The electron temperature and the electron density of the plasmas were also calculated from the lines intensity and stark broadening of emission spectral line respectively. The experimental results indicated that with the increase in the NaCl additive, the spectral intensity, signal-to-background ratio, the electron temperature, and the electron density all went up firstly and then down. When 15% NaCl was added, the radiation intensity of the plasma reached the maximum value, the spectral lines intensity of element Mn, K, Fe, and Ti increased by 39.2%, 42.5%, 53.9% and 33.8% compared to that without additive respectively, the spectral signal-to-background ratio increased by 64.4%, 84.3%, 44.55% and 58.2% respectively, while the electron temperature and the electron density of the plasmas were heightened by 0.17 times and 0.36 times respectively.
Key words:Laser-induced plasma;Sample additive;Spectrum intensity;Electron temperature;Electron density
[1] Cravetchi I V, Taschuk M T, Tsui Y Y, et al. Anal. Bioanal. Chem., 2006, 385(2): 287. [2] Kuzuya M,Matsumoto H,Takechi H,et al. Appl. Spectroscopy,1993,47(10):1659. [3] Lin King-chuen, Huang Jer-shing. Metallurgical Analysis, 2008, 28(1): 97. [4] Pu X Y, Cheung N H. Appl. Spectrosc., 2003, 57(5): 588. [5] LI Lan, CHEN Guan-ying, ZHANG Shu-dong, et al(李 澜, 陈冠英, 张树东, 等). Journal of Atomic and Molecular Physics(原子与分子物理学报), 2003, 20(3): 343. [6] SHOU Man-li, JIANG Gui-lan(寿曼立, 姜桂兰). Atomic Spectrochemical Analysis(原子光谱化学分析), 1994, 216. [7] CHEN Dong, LIU Wen-qing, LI Hong-bin, et al(陈 东, 刘文清, 李宏斌, 等). Chinese Journal of Lasers(中国激光), 2005, 32(10): 1353. [8] Glumac N. J. Appl. Phys., 2005, 98(5):053301. [9] Martinez A R, Sobral H, Muniz M V. Applied Surface Science, 2005, 248: 32. [10] XUE Si-min, CHEN Guan-ying, SU Mao-gen, et al(薛思敏, 陈冠英, 苏茂根, 等). Journal of Atomic and Molecular Physics(原子与分子物理学报), 2006, 23(1): 39. [11] CHEN Jin-zhong, LI Hong-yan, WEI Yan-hong, et al(陈金忠, 李宏彦, 魏艳红, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2006, 26(2): 218. [12] Naeem T M, Matsuta H, Wagatsuma K, et al. Spectrochimica Acta Part B, 2003, 58(5): 891. [13] Sturm V,Noll R. Appl. Opt., 2003,42(30):6221. [14] CHEN Jin-zhong, ZHANG Xiao-ping, GUO Qing-lin, et al(陈金忠, 张晓萍, 郭庆林, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2009, 29(2): 483. [15] Shaikh Nek M, Kalhoro M S, Baig M A. Metallurgical Analysis, 2008, 28(1): 127. [16] Zhang Baohua, Liu Wenqing. Journal of Atomic and Molecular Physis, 2008, 25: 1023. [17] Griem H R. Plasma Spectroscopy, New York: McGraw-Hill, 1964. 375. [18] Cabalín L M, Romero D, García C C, et al. Anal. Bioanal. Chem., 2002, 372(2): 352. [19] Zeng Xianzhong, Mao S S, Liu Chunyi, et al. Spectrochimica Acta Part B, 2003, 58: 867. [20] Ying Minju, Xia Yueyuan, Sun Yuming, et al. Applied Surface Science, 2003, 207: 227. [21] Abdellatif G, Imam H. Spectrochimica Acta Part B, 2002, 57: 1155. [22] Gornushkin I B, Omenetto N, Smith B W, et al. Appl. Spectrosc., 2004, 58: 1023. [23] Lopez A J, Luque M D, De Castro. Appl. Spectrosc., 2003, 57(3):349.