Abstract:Niuhuang Jiedu tablets were digested with HNO3-H2O2 system by microwave digestion. The fourteen trace elements of As, Ca, Mg, Al, Mn, Sr, Ba, Se, Ni, Cd, Cu, Zn, Mo and Pb in the solution were determined by ICP-AES. The ICP-AES result proved to be reliable by adding standard recovery experiment to the process. By comparison with the result of chemical experiment, thr present method was accurate, quickly-accessible, and convenient. It was used for Niuhuang Jiedu tablets with result satisfactory.
郑永军,赵斌,尤进茂. 微波消解ICP-AES法测定牛黄解毒片中的微量元素[J]. 光谱学与光谱分析, 2006, 26(06): 1155-1157.
ZHENG Yong-jun, ZHAO Bin, YOU Jin-mao. Determination of Trace Elements in Niuhuang Jiedu Tablets by Microwave Digestion and ICP-AES . SPECTROSCOPY AND SPECTRAL ANALYSIS, 2006, 26(06): 1155-1157.
[1] MENG Xian-shu, CHEN Fa-kui(孟宪纾,陈发奎). Chinese Traditional Patent Medicine Analysis(中成药分析). Beijing: The People Hygiene Press(北京: 人民卫生出版社),1990. 237. [2] CHEN Li-na, WU Li-lan(陈丽娜,吴丽兰). China Journal of Chinese Material Medicine(中国中药杂志),2002,27(4):315. [3] LIU Yan-ming(刘彦明). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2000,20(3):373. [4] ZHANG Qi-feng, PENG Shan-shan, LI Li, et al(张奇凤, 彭珊珊, 李 丽, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析),1999,19(3):392. [5] XING Xiao-mei, MEI Jian-ming(邢晓梅, 梅建鸣). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2003,23(5):995. [6] Charles B Boss, Kenneth J Fredeen. Concepts Instrmentation and Techniques in Inductively Coupled Plasma Optical Emission Spectrometry, Norwalk: The Perkin-Elmer Corporation, 1999. 36.