Abstract:The principle of tunable diode laser absorption spectroscopy and harmonic detection technique was introduced. An experimental device was developed by point sampling through small multi-reflection gas cell. A specific line near 1 653.7 nm was targeted for methane measurement using a distributed feedback diode laser as tunable light source. The linearity between the intensity of second harmonic signal and the concentration of methane was determined. The background content of methane in air was measured. The results show that gas sensors using tunable diode lasers provide a high sensitivity and high selectivity method for city gas pipeline leak detection.
[1] Reid J, Labrie D. Appl. Phys. B. 1981, 26: 203. [2] Werle P. Spectrochimica Acta Part A. 1998, 54: 197. [3] Allen M G. Measurement Science and Technology 1998, 9: 545. [4] Uehara K, Tai H, Kimura K. Sensors and Actuators B. 1997, 38-39: 136. [5] Frish M B, White M A, Allen M G. Proc. SPIE,2001, 4199: 19. [6] Iseki T, Tai H, Kimura K. Measurement Science and Technology, 2000, 11: 594. [7] Arroyo M P, Hanson R K. Appl. Opt.,1993, 32(30): 6104. [8] Li H, Rieker G B, Liu X, et al. Appl. Opt., 2006, 45(5): 1052. [9] KAN Rui-feng,LIU Wen-qing, ZHANG Yu-jun, et al(阚瑞峰,刘文清,张玉钧,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2006, 26(3): 392. [10] Doussin J F, Dominique R, Patrick C. Appl. Opt.,1999, 38(19): 4145. [11] Rothman L S, et al. Journal of Quantitative Spectroscopy and Radiative Transfer,2005, 96: 139.