Abstract:In the tissue composition measurements in vivo based on diffuse spectroscopy, the tissue differences or variations could induce a big uncertainty. Monitoring the tissues’ optical characteristics is necessary to improve the measurement accuracy. The measurement with single light source detector separation (SDS) is not suitable to be applied widely because the absorbance of diffuse light dose not vary with SDSs linearly then. The results with one SDS hardly are transferred to that with other SDSs. In this paper, we use two SDSs to perform a differential measurement and acquire the effective attenuation coefficient (EAC) for in vivo tissues, independent of the used SDSs as a comprehensive optical property related to tissue absorption and scattering. An optical fiber leads incident light, and two detectors are designed for the two SDSs, arranged circularly with multiple optical fibers. The SDSs applied are 0.6 and 2.0 mm, respectively. The acquired EAC spectra can monitor the tissue composition variations or tissue condition fluctuations. In tralipid solutions were used to mimic tissues, and the EAC spectra of glucose concentration, hemoglobin concentration, particle density and temperature in the waveband of 1 000~1 300 nm were investigated and compared. The results show that the EAC spectra mainly demonstrate the tissue absorption caused by the variables. The EAC spectra of hemoglobin show a similar characteristic with hemoglobin’s absorption as there is a more considerable absorption at 1 000~1 200 nm and a lower at 1 200~1 300 nm. The EAC spectra caused by temperature changes appear similar to the water’s absorption change under varying temperatures. The EAC spectra caused by scattering change show less specificity, and the spectra of glucose and particle density seem similar in that they only affect scattering as glucose has less absorption at this waveband. Furthermore, the EAC spectra of human bodies are investigated and their differences between individuals or test positions, including fingers, palms, backs of hands, and lateral arms. These EAC spectra of human bodies can demonstrate the tissue differences caused by hemoglobin, water and temperature etc. In summary, this EAC spectrum measurement approach is especially suitable for in vivo tissues and provides a new way for monitoring in vivo tissues in real-time as a good indicator of absorption or scattering of the tissues.
Key words:Near-infrared spectroscopy; Effective attenuation coefficient; In vivo tissue; Noninvasive composition measurement; Hemoglobin; Blood glucose; Temperature
刘 瑾,付润娟,韩同帅,刘 蓉,孙 迪. 基于有效衰减系数直接测量的人体光谱特征分析[J]. 光谱学与光谱分析, 2022, 42(09): 2746-2751.
LIU Jin, FU Run-juan, HAN Tong-shuai, LIU Rong, SUN Di. Spectral Analysis of Human Tissues Based on a Direct Effective
Attenuation Coefficient Measurement. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(09): 2746-2751.
[1] XU Ke-xin, GAO Feng, ZHAO Hui-juan(徐可欣,高 峰,赵会娟). Biomedical Photonics(生物医学光子学). Beijing: Science Press(北京:科学出版社), 2011.
[2] https://www.masimo.com
[3] https://www.orsense.com
[4] Yadav J, Rani A, Singh V, et al. Biomedical Signal Processing and Control, 2015, 18: 214.
[5] Liu J, Zhu C, Jiang J, et al. Biomedical Optics Express, 2018, 9(12): 5903.
[6] Mourant J R, Bigio I J, Jack D A, et al. Applied Optics, 1997: 36(22), 5655.
[7] Liu H. Applied Optics, 2001, 40(10):1742.
[8] Leyre S, Meuret Y, Durinck G, et al. Applied Optics, 2014, 53(10): 2117.
[9] Chiarelli A M, Low, K A, Maclin E L. Photonics, 2019, 6(3): 79.
[10] Chiarelli A M, Maclin E L, Low K A, et al. Neurophotonics, 2017, 4(2): 021103.
[11] Liu J, Han T, Jiang J, et al. Biomedical Optics Express, 2019, 10(9): 4839.
[12] CAO Hai-qing, HAN Tong-shuai, LIU Xue-yu, et al(曹海青, 韩同帅, 刘雪玉, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2019, 39(12): 3711.
[13] Han T, Liu J, Liu X, et al. SPIE Conference, Optical Diagnostics and Sensing XIX: Toward Point-of-Care Diagnostics, 2019.
[14] Farrell T J, Patterson M S, Wilson B. Medical Physics, 1992, 19(4): 879.
[15] Min X, Liu R, Fu B, et al. Optics and Laser Technology, 2017, 91: 7.
[16] Kohl M, Cope M , Essenpreis M, et al. Optics Letters, 1994, 19: 2170.
[17] FAN Yi-chen, LU Qi-peng, DING Hai-quan(樊奕辰,卢启鹏,丁海泉,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2013, 33(2): 349.
[18] GE Qing, HAN Tong-shuai, LIU Rong, et al(葛 晴, 韩同帅, 刘 蓉, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2020, 40(5): 1483.