Design and Application of the Discrimination Filter for Near-Infrared Spectroscopic Analysis
SUN Xue-hui1, ZHAO Bing2, LUO Zhen2, SUN Pei-jian1, PENG Bin1, NIE Cong1*, SHAO Xue-guang3*
1. Zhengzhou Tobacco Research Institute of China National Tobacco Corporation, Zhengzhou 450001, China
2. China Tobacco Henan Industry Co., Ltd., Zhengzhou 450000, China
3. Research Center for Analytical Sciences, College of Chemistry, Nankai University, Tianjin 300071, China
Abstract:Chemometrics has been widely applied in near-infrared (NIR) spectroscopic analysis for quantitative detection and discrimination. However, new methods are still needed to simplify data processing and modeling to speed up the analysis and improve the convenience in practical uses. As a new type of technique for spectroscopic measurement and computation, the multivariate optical computing (MOC) technique is employed in spectroscopic analysis. The technique uses multivariate information in the spectrum to achieve quantitative computation and discrimination through the designed filters. In this work, the filters for discrimination analysis of near-infrared spectroscopy was designed based on principal component analysis (PCA) and Fisher’s discrimination criterion. The spectra of the calibration samples can be projected into a two-dimensional space by the two filters to achieve an optimized classification, and a confidence ellipse can be obtained for each class of the samples. The ellipse can be used as a model for the discriminating the prediction samples. The distance of a prediction sample to the model is a good measurement of its classification. The samples with a distance less or equal to 1 are classified into the same class of the model, but those with a distance larger than 1 is excluded from the class, and the larger the distance, the bigger the dissimilarity. The proposed method was tested with the NIR spectra of 460 samples of tobacco leaf in three different parts of the plant and 73 samples of the medicinal capsules (amoxicillin granules) produced by four producers. The true positive rate can be higher than 90%, except for the tobacco samples and even higher than 95% for the capsule samples. However, the false-positive rate of the tobacco samples is still not so satisfactory due to the similarity of the NIR spectra. Using near infrared spectroscopy, the proposed method may provide a good technique for quality control, product detection and production monitoring in different fields.
孙学辉,赵 冰,骆 震,孙培健,彭 斌,聂 聪,邵学广. 近红外光谱判别分析滤波器的设计与应用[J]. 光谱学与光谱分析, 2022, 42(02): 399-404.
SUN Xue-hui, ZHAO Bing, LUO Zhen, SUN Pei-jian, PENG Bin, NIE Cong, SHAO Xue-guang. Design and Application of the Discrimination Filter for Near-Infrared Spectroscopic Analysis. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(02): 399-404.
[1] Moros J, Garrigues S, de la Guardia M. V Trends in Analytical Chemistry, 2010, 29(7): 578.
[2] Pasquini C. Analytica Chimica Acta, 2018, 1026: 8.
[3] Shao X G, Bian X H, Liu J J, et al. Analytical Methods, 2010, 2(11): 1662.
[4] Shao X G, Leung A K M, Chau F T. Accounts of Chemical Research, 2003, 36(4): 276.
[5] Shao X G, Ma C X. Chemometrics and Intelligent Laboratory Systems, 2003, 69(1-2): 157.
[6] Shao X G, Cui X Y, Wang M, et al. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2019, 213: 83.
[7] Zou X B, Zhao J W, Povey M J W, et al. Analytica Chimica Acta, 2010, 667(1-2): 14.
[8] Cai W S, Li Y K, Shao X G. Chemometrics and Intelligent Laboratory Systems, 2008, 90(2): 188.
[9] Xu H, Liu Z C, Cai W S, et al. Chemometrics and Intelligent Laboratory Systems, 2009, 97(2): 189.
[10] Zhang J, Cui X Y, Cai W S, et al. Science China-Chemistry, 2019, 62(2): 271.
[11] Li Y K, Shao X G, Cai W S. Talanta, 2007, 72(1): 217.
[12] Jing M, Cai W S, Shao X G. Chemometrics and Intelligent Laboratory Systems, 2010, 100(1): 22.
[13] Shan R F, Mao Z Y, Yin L H, et al. Analytical Methods, 2014, 6(13): 4692.
[14] Mancini M, Taavitsainen V M, Toscano G. Journal of Chemometrics, 2019, 33(7): e3145.
[15] Bandara D, Hirshfield L, Velipasalar S. Journal of Near Infrared Spectroscopy, 2019, 27(3): 206.
[16] Bialkowski S E. Analytical Chemistry, 1986, 58: 2561.
[17] Nelson M P, Aust J F, Dobrowolski J A, et al. Analytical Chemistry, 1998, 70(1): 73.
[18] Faulkner S T, Rekully C M, Lachenmyer E M, et al. Applied Spectroscopy, 2019, 73(3): 304.
[19] Brooke H, Baranowski M R, McCutcheon J N, et al. Analytical Chemistry, 2010, 82(20): 8427.
[20] Jones C M, Price J, Dai B, et al. Analytical Chemistry, 2019, 91(24): 15617.
[21] Li X Y, Xu Z H, Cai W S, et al. Analytica Chimica Acta, 2015, 880: 26.
[22] Liu Y, Cai W S, Shao X G. Chemometrics and Intelligent Laboratory Systems, 2015, 149: 22.