Abstract:In order to meet the needs of rapid and accurate detection of in-situ water total alkalinity, a mini online rapid tester of total alkalinity of trace in-situ water was designed by combining sequential injection analysis (SIA) and continuous spectrum detection. The system mainly applies the SIA and continuous spectrum detection method to the total alkalinity automatic titration detection process by designing the titration cell and conducting experimental research on a new method of determining the titration’s critical value by the continuous spectrum detection method. Based on the national standard of the determination on total alkalinity in industrial circulating cooling water and surface water, the detection process of in-situ water quality alkalinity was designed. Also, on the basis of the sequential injection technology as the standard of controlled titration process, under the conditions of continuous spectral scanning measurement of the solution detection process, phenolphthalein and methyl orange were used as indicators to perform a titration analysis on the total alkalinity of water quality. The phenolphthalein alkalinity and methyl orange alkalinity titration process were monitored by continuous spectral scanning. The peak value at 552 nm of the absorbance curve was used as the phenolphthalein titration threshold value. The absorbance curve’s peak value shifting from 465 to 504 nm was selected as judging conditions for the critical value of basic orange titration. The optimal indicator dosages were analyzed by the absorbance curves of the solutions obtained by adding different doses of phenolphthalein and methyl orange indicators, which were 0.01 and 0.04 mL, respectively. The system applied least-squares fitting algorithm to establish a regression model for total alkalinity determination and optimized the detection system and process. The experimental results indicate that the total alkalinity of water quality is linearly related to hydrochloric acid consumption in the range of 0.20 to 25.00 mmol·L-1 and the fitting coefficient of the working curve is no less than 0.994 2. The relative standard deviation (RSD) of the total alkalinity measurement’s repeatability is between 0.207 and 1.151%. Waste liquid volume is no larger than 16 mL. The lowest detection limit is 0.03 mmol·L-1. The recovery of spiked samples is between 97.2% and 102.3%. Also, there is no significant difference between the experimental results and the national standard method. The new method for determining the critical value of titration using continuous spectrum detection method is of great significance to improve the technical performance of the total alkalinity detector of water quality. It can be applied to many kinds of monitoring application platforms such as system grid monitoring of surface water, circulating cooling water, and breeding circulating water.
李 文,程 李,王利民,徐明刚,张 鹏. 微量原位水质总碱度在线检测新方法研究[J]. 光谱学与光谱分析, 2021, 41(05): 1477-1482.
LI Wen, CHENG Li, WANG Li-min, XU Ming-gang, ZHANG Peng. Study on New Method of Online Detection of Total Alkalinity of Trace In-Situ Water Quality. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(05): 1477-1482.
[1] GB/T 15451—2006. Industrial Circulating Cooling Water Determination of Total and Composite Alkalinity(工业循环冷却水总碱及酚酞碱度的测定). National Standards of the People’s Republic of China(中华人民共和国国家标准).
[2] CAO Sheng-xian, ZHAO Zhen-chao, LI Si-bo(曹生现, 赵振超, 李思博). CIESC Journal(化工学报), 2015, 66(7): 2649.
[3] LU Ye-ting, YOU Zhao-jin, SHEN Ya-fang(卢叶艇, 游兆金, 沈亚芳). Nuclear Power Engineering(核动力工程), 2017, 38(S2): 131.
[4] Howarth J H, Glen N F, Jenkins A M. The Use of Fouling Monitoring Technigues: Understanding Heat Exchanger Fouling and Its Iitigation. New York: Bege II House Inc., 1999,309.
[5] LUO Guo-zhi, CHEN Xiao-qing, TAN Hong-xin(罗国芝, 陈晓庆, 谭洪新). Freshwater Fisheries(淡水渔业), 2018, 48(2): 100.
[6] Leire Kortazar, Bastien Duval, Olaia Liñero. Microchemical Journal, 2020, 152(c): 104345.
[7] Leire Kortazar, Demetrio Milea, Olivia Gómez-Laserna. Trends in Analytical Chemistry, 2019, 114: 69.
[8] WANG Ai-jun, WANG Cong, SHI Chao-ying(王爱军, 王 聪, 石超英). Journal of Ocean Technology(海洋技术学报), 2014, 33(2): 81.
[9] QIN Yu-hua, WANG Dong-bing, ZHANG Hai-yan(秦玉华, 王东兵, 张海燕). Chinese Journal of Scientific Instrument(仪器仪表学报), 2011,32(11): 2585.
[10] YANG Ze-ming, LI Cai, LU Gui-xin(杨泽明, 李 彩, 卢桂新). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2019, 39(2): 589.
[11] LI Wen, LÜ He, XU Ming-gang(李 文,吕 赫,徐明刚). Chinese Journal of Luminescence(发光学报), 2019, 40(7): 930.
[12] Wang Chingyu, Hsu Chengche. Environmental Science & Technology, 2019, 53(18).
[13] Beganovic Anel, Moll Vanessa, Huck Christian W. Molecules, 2019, 24(20): 3696.