Abstract:It is important and challenging to select the variable for the spectral information automatically and establish a sparse linear model between the spectrum and the sample content under the circumstance that the near-infrared spectral information is much larger than the sample size. In this paper, Elastic Net was used for the measurement of o-cresol in the polyphenylene ether by utilizing the near infrared spectroscopy and a quantitative calibration model between near infrared spectroscopy and o-cresol content was established. Then, the model prediction effect is compared with the Lasso method. In the case where the number of variables is much larger than that of the samples. Although Lasso method can achieve variable selection, the prediction accuracy of the model is affected due to excessive compression to variable coefficients. Elastic Net avoids excessive censorship by increasing L2 penalty, which can improve model prediction accuracy. In order to verifymodel performance indicators ofElastic Net method, we use the complex correlation coefficient R2 and the adjusted complex correlation coefficient R2a to evaluate the interpretability of the model, meanwhile, the prediction accuracy of the model is evaluated by using the mean relative prediction error MRPE and the prediction correlation coefficient Rp. Lasso method to establish the model performance indicators are: R2=0.94,R2a=0.93,MRPE=4.51%,Rp=0.96;Elastic Net method performance indicators are: R2=0.97,R2a=1,MRPE=3.25%,Rp=0.98. From the result we could draw the conclusion that Elastic Net’s model is better than Lasso method. A sparse linear model with higher interpretability and high prediction accuracy can be obtained by the Elastic Net regression.
[1] LU Wan-zhen(陆婉珍). Modern Near Infrared Spectroscopy Analytical Technology,2nd Ed.(现代近红外光谱分析技术, 第2版). Beijing: China Petrochemical Press(北京:中国石化出版社),2010.
[2] Huang X Y,Teye E,Sam-Amoah L K,et al. Analytical Methods,2014,6(14):5008.
[3] SHI Ting,LUAN Xiao-li,LIU Fei(史 婷,栾小丽,刘 飞). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2017, 37(4): 1058.
[4] TANG Shou-peng,YAO Xin-feng,YAO Xia,et al(汤守鹏,姚鑫锋,姚 霞,等). Chinese Journal of Analytical Chemistry(分析化学),2009, 37(10): 1445.
[5] Zou H,Hastie T. Journal of the Royal Statistical Society. Series B(Methodological),2005, 67(1):301.
[6] Tibshirani R. Journal of the Royal Statistical Society. Series B(Methodological),1996, 15(1):267.
[7] LIU Liu,TAO Da-cheng(刘 柳,陶大程). Journal of Data Acquisition and Processing(数据采集与处理),2015, 30(1):35.
[8] HE Xiao-qun,LIU Wen-qing(何晓群,刘文卿). Applied Regression Analysis(应用回归分析). Beijing:China Renmin University Press(北京:中国人民大学出版社),2015.
[9] ZHANG Yu(张 玉). Journal of Jiangsu Institute of Education·Natural Sciences(江苏教育学院学报·自然科学),2012, 28(3):28.
[10] LIU Ran,YANG Xiao-li,XU Yun-hui,et al(刘 冉,杨晓丽,徐云惠,等). Guangzhou Chemical Industry(广州化工),2013,41(15):128.
[11] WANG Xin(王 欣). Science & Technology Information(科技资讯),2013, 15: 2.
[12] Tong Peijin,Du Yiping,Zheng Kaiyi,et al. Chemometrics and Intelligent Laboratory Systems,2015, 143: 40.
[13] Khan M H R, Shaw J E H. Statistics and Computing, 2016, 26(3): 725.
[14] WANG Da-rong,ZHANG Zhong-zhan(王大荣,张忠占). Journal of Applied Statistics and Management(数理统计与管理), 2010, 29(4):616.